Laserfiche WebLink
Hospit " parlor Water - Summer, Phase I <br /> Faria Dairy#130 ` 130-11 waste charts,phase I <br /> #Hosp.Cows: 15 296'of lactating cows <br /> Milk Production: 5 gals/cow 75 gals/day(milk) <br /> #Milkings/Day 2 <br /> #of Strings: 1 <br /> Sprnk.Head Flow: i5 gals/min. <br /> #of Sprnk Heads: 9 <br /> 0.75 mins.on <br /> 2.00 mins.off <br /> Sprnk.Cycle 0.75 mins.on <br /> 2.00 mins.off <br /> 0.75 mins.on <br /> 11.3 gals/Cycle/sprk <br /> Gals required for one floor flush 5Q0 <br /> Floor Flushes: Floor Flushes <br /> 0 Once Per String per milking <br /> 0 Once every other string per milking 1000 gals <br /> 0 Once every third string per milking <br /> At Cow Wash Cycles per day <br /> 0 1 per string per day <br /> 0 2 per string per day 2 total wash cycles/day <br /> 0 3 per string per day <br /> Plate Cooler <br /> •Well Water 1.5 gals water/gals milk <br /> 0 Chilled Water <br /> Refrigeration Condensors <br /> Water Cooled <br /> - 1 5 gals water/gals milk <br /> 0 Alr Cooled :1 <br /> Water From Plate Cooler Recycled <br /> •Yes 113 gals recyled per day <br /> 0 No <br /> Gals Water/day through sprk: 203 gals <br /> Water recycled from plate: 113 gals <br /> Water Recycled To Water Troughs <br /> 0 Yes <br /> 0 No <br /> #Milk Tank Washes: 1 150 gals ea. 150 gals. <br /> #Milk Pipe Line Washes 2 275 gals ea 550 gals. <br /> #Misc. Floor Washes: 2 200 gals ea 400 gals. <br /> Water From plate cooler/sprinklers: 203 gals. <br /> Water From Floor Flushes: 1,000 gals. <br /> Total Water: 2,303 gal/day <br /> Parlor Water Charts <br /> VIB <br />