My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0010676 SSCRPT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SHELLEY
>
10601
>
2600 - Land Use Program
>
PA-1500198
>
SU0010676 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2019 4:25:49 PM
Creation date
9/9/2019 10:14:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0010676
PE
2622
FACILITY_NAME
PA-1500198
STREET_NUMBER
10601
Direction
N
STREET_NAME
SHELLEY
STREET_TYPE
RD
City
LINDEN
Zip
95236-
APN
06719005
ENTERED_DATE
10/27/2015 12:00:00 AM
SITE_LOCATION
10601 N SHELLEY RD
RECEIVED_DATE
10/26/2015 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\S\SHELLEY\10601\PA-1500198\SU0010676\SURSUB RPT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.2 Description of All Past On-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified at the Project Site: Past on-site potentials for <br /> contamination are low. The property has been used for agricultural purposes for more than 10 <br /> years. Historically there have been no underground storage tanks. The owner has no knowledge <br /> of improper above ground storage of chemicals on the subject parcel. <br /> 3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence of <br /> buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> ' There are buildings on the property where some fertilizers and other chemicals for agricultural 0.3) <br /> use are stored. There are no above ground fuel tanks on the site. On-site storm water dissipates <br /> _ through either percolation, evaporation, or runoff to the river. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential �J <br /> �- for contamination is low. The subject parcel is located in agricultural community. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Present off-site <br /> potential for contamination is low. There is no knowledge of below ground sources of C3 45� <br /> contamination in the area of the project site that has or may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth to <br /> ground water in this area is approximately 190 feet. Due to this depth, any pesticides, <br /> insecticides, and fertilizers used on the property in the past or present would have a moderate <br /> impact to the groundwater. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers for fuel storage <br /> tanks on this site,thus the potential for contamination is low. As was stated above, any <br /> ` pesticides, insecticides, and fertilizers used on the site do not pose any significant potential for �S <br /> contamination to the project site, and no mitigation measures are recommended. <br /> ► 5.2 The Report is Inclusive: All information in this report does not reference any other 2� <br /> documents that are not contained in this report. <br /> y <br /> .. 2 <br /> r Y:\DMDOC\2015\1554\SSR REPORT.dou <br />
The URL can be used to link to this page
Your browser does not support the video tag.