Laserfiche WebLink
/3.3 Description of all current on-site potential and/or known above and below ground <br /> sources of contamination identified at the project site: Presently, there are no underground <br /> storage tanks on the property and visual inspection did not produce any evidence of buried <br /> containers, as well as no odors that would be associated with buried chemical tanks. There is an <br /> existing ag pump utilizing above ground fertilizer distribution tanks. <br /> /3.4 Description of all past off-site potential and/or known above and below ground sources <br /> of contamination identified in the area of the project site: Past off-site potential for <br /> �., contamination is low. Other sources of potential contamination is the surrounding vineyards and <br /> the chemicals used in their farming operation. There is no knowledge of below ground sources <br /> of contamination in the area of the project site that has or may impact the project site. <br /> 3.5 Description of all present off-site potential and/or known above and below ground <br /> sources of contamination identified in the area of the project site: Present off-site potential <br /> for contamination is low. Other sources of potential contamination is the surrounding vineyards <br /> and the chemicals used in their farming operation. There is no knowledge of below ground <br /> sources of contamination in the area of the project site that has or may impact the project site. <br /> X4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> �4.1 Evaluation of each potential and/or known source of contamination identified for any <br /> real and/or potential threat to human health and the environment: The depth to ground <br /> water in this area is approximately 190 feet. Due to this depth, any pesticides, insecticides, and <br /> fertilizers used on the property in the past or present would have a mimmal impact to the ground <br /> water. The use of approved best management practices for the containment of soil or any <br /> contaminates by straw waddles and other practices to reduce the introduction of any dirt or <br /> contaminates into the storm runoff system will be required at the time of any future construction <br /> per County Building Department. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> ` 5.1 Discussion of the above evaluation: The aforementioned farming practices creates the only <br /> potential for contamination. There is natural drainage swale thro gh the middle, and eastside of <br /> the subject parcel{The potential for contamination would be low)and no mitigation measures <br /> are recommended at this time. JJI <br /> 2 <br /> c90625SContamination Report 042406 <br />