SU0008700
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15300
>
2600 - Land Use Program
>
PA-1000131
>
SU0008700
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:37 AM
Creation date
9/9/2019 10:36:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0008700
PE
2627
FACILITY_NAME
PA-1000131
STREET_NUMBER
15300
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
APN
02519016 18 19
ENTERED_DATE
4/4/2011 12:00:00 AM
SITE_LOCATION
15300 N THORNTON RD
RECEIVED_DATE
4/4/2011 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\15300\PA-1000131\SU0008700\APPL.PDF \MIGRATIONS\T\THORNTON\15300\PA-1000131\SU0008700\CDD OK.PDF \MIGRATIONS\T\THORNTON\15300\PA-1000131\SU0008700\EH COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
q. All off-site and PUE utility line improvements shall be in conformance with the current Improvement <br /> Standards and Specifications of the County of San Joaquin. These improvement plans and <br /> specifications are subject to plan check and field inspection fees and must be approved by Public <br /> Works prior to issuance of the occupancy permit. (Development Title Sections 9-240 and 9-1100) <br /> r. All traffic signs and markings shall conform to the latest edition of the Manual on Uniform Traffic <br /> Control Devices andtor San Joaquin County Standards and shall be shown on the improvement <br /> plans. (Development Title Section 9-1150.2) <br /> s. The project shall be served by a public water system conforming to the requirements of <br /> Environmental Health and Public Works. The system shall provide adequate domestic and fire water <br /> supply in conformance with the requirements of the County Fire Warden and the local fire district. <br /> The applicant shall install a County Standard water meter. Service shall be provided by County <br /> Service Area 31,Zone W. (Development Title Section 9-1120.2) . <br /> t. The project shall be served by a public sewer collection and treatment system constructed in <br /> conformance with the requirements of Environmental Health and Public Works, Service shall be <br /> provided by CSA 31_ (Development Title Section 9-1105.2) <br /> (1) A wastewater questionnaire shall be submitted to Public Works. <br /> (2) Sewer calculations shall be submitted to Public Works, including sewerdemand projections, and <br /> must comply with applicable agreements attached to the parcels related to the proposed <br /> development. <br /> (3) The applicant shall comply with all Memorandums of Understanding,including but not limited to <br /> document A-07-234, and guidelines associated with the sewer connection and effluent treatment <br /> provided by the City of Lodi. <br /> (4) The applicant shall ensure that the maximum salinity electrical conductivity for sewer system <br /> effluent discharges is 1051 umhos/cm, based on June 15, 2010,quarterly well test results, unless <br /> otherwise approved by the City of Lodi as part of their salinity plan. <br /> (5) Self-regenerating water softeners,those that backwash a brine solution into the sewer,are <br /> prohibited. <br /> (6) Appropriate grease traps in conformance with the requirements of Environmental Health and <br /> Public Works shall be installed. Plans,specifications, and an operation and maintenance plan <br /> shall be submitted with the final site plan for review and approval prior to the release of building <br /> permits. <br /> (7) The applicant shall pay annual sewer charges that are based upon projected demand or the <br /> prior year's actual water use. <br /> (8) Total sewer demand shall be limited per the wilf-serve letter on file for this project. <br /> u. The project shall be served by a public terminal drainage system to meet the requirements of San <br /> Joaquin County Development Standards and to provide adequate drainage for the project site. <br /> Service shall be provided by CSA 31. (Development Title Section 9-1135.3) <br /> v. The project shall be served by a public street lighting system. Service shall be provided by CSA 31. <br /> San Joaquin County PA-1000131\Highway 12 Investors <br /> Community Development Page 11 <br />