Quarterly Monitoring Report—Fourth Quarter of 2009 Page 6 <br /> TURNER ROAD VINTNERS January 22,2010 <br /> WKA No. 5279.03 <br /> _ • Nitrate-as-nitrogen was below the laboratory-reporting limit of 0.50 mg/L in <br /> MWI, MW2, and MWS. Nitrate-as-nitrogen was detected in the sample set at <br /> 17 mg/L in MW3 and at 3.4 mg/L in MW4; <br /> • pH in the sample set ranged from 6.81 in MW5 to 7.51 in MW2; <br /> _ • Specific Conductance in the sample set ranged from 720 mg/L in MW2 to 1,800 <br /> mg/L in MW5; <br /> • Sulfate as SO4 in the sample set ranged from 6.81 in MW5 to 7.51 in MW2; <br /> • TDS concentrations in the sample set ranged from 460 milligrams per liter (mg/L) <br /> in MW2 to 1,200 mg/L in MW5. <br /> Table 3 is a summary of historical groundwater analyses results from the site and includes the <br /> most recent laboratory results. Time series plots of the parameters TDS (plus groundwater <br /> elevation) for each of the monitoring wells are included as Charts 1 through 5. Appendix A <br /> includes the laboratory report for this sampling event and a copy of the chain-of-custody. <br /> 5.3 Data Quality <br /> All samples were received by the laboratory under documented chain-of-custody. United States <br /> Environmental Protection Agency SW-846 (EPA 2000) protocols for sample storage and <br /> preservation were followed. Qualifiers were attached to all pH results since the samples <br /> exceeded the analytical method hold time. <br /> The spike recovery was outside the QC acceptance limits for the MS and/or MSD due to analyte <br /> concentration at 4 times or greater the spike concentration. The QC batch was accepted based on <br /> LCS and/or LCSD recoveries within the accepted limits. <br /> Based on the results of laboratory analyses and review of sampling procedures, laboratory <br /> quality assurance and quality control, and review of historical analytical results, the data appears <br /> adequate for the use intended. <br /> 6.0 SUMMARY <br /> Quarterly groundwater monitoring of the process wastewater treatment well network was <br /> conducted on December 29 and 30, 2009 at the Turner Road Vintners' facility. The DTW and <br />