Laserfiche WebLink
more than 10 years. Historically there have been no underground storage tanks. The owner has <br /> no knowledge of above or below ground surfaces of contamination on the subject parcel. There <br /> is one above ground portable fuel tank on subject parcel. <br /> ` A search for Use Reports and Permits did not yield any concerns for sources of contamination <br /> (see Appendix). All pesticides and fertilizers applied were done under Permit No. 3904556 & <br /> 3904534. (see Appendix for the entire inventory).] <br /> 3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> ` Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> of buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> There is an above ground portable fuel tank on the site. On-site storm water is contained on site <br /> and dissipates through either percolation or evaporation. <br /> ` 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential (3.Zo <br /> for contamination is low. The subject parcel is located in agricultural community. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Present off-site <br /> potential for contamination is low. There is no knowledge of below ground sources of (3 •5) <br /> contamination in the area of the project site that has or may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth to 1, <br /> potable water is 200 feet. Due to the depth, any pesticides, insecticides, and fertilizers used on ([� <br /> the property in the past or present would have a minimal impact to the potable water. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers on this site; thus, <br /> the potential for contamination is low. As previously stated, any pesticides, insecticides, and (5 I <br /> fertilizers used on the site do not pose any significant potential for contamination to the project <br /> site, and no mitigation measures are recommended. <br /> 5.2 The Report is Inclusive: All information in this report does not reference any other 1 <br /> documents that are not contained in this report. <br /> 5.3 Report was Signed Dated and Stamped: See end of report. <br /> 2 <br /> Y:\DMDOD\2013\1344\SSCR Addended May 2013.doc <br />