Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> / 7 q?`z�COMMUNITY DEVELOPMENT DEPARTMENT <br /> )-1610 E.HAZELTON AVE.STOMON,CA 95205-6232 <br /> C PHONE:209/4683121 FAX:209/468-3163 <br /> DATE: January 9, 2019 <br /> PA-1800200(SA) <br /> Property owner: Rufino M &Alicia Hernandez <br /> Applicant: Same <br /> APN/Address: 226-110-28, 6299 East Ripon Rd, Manteca <br /> Planner: Christine Luckasen <br /> Project Description: Truck Parking With Use Of Existing Building <br /> BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The <br /> following conditions shall be addressed prior to submittal of a building permit application to the <br /> Building Inspection Division: <br /> 1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design <br /> Professional (architect or engineer)for each structure or building, showing compliance with <br /> The 2016 California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy <br /> and Fire Codes as may be applicable. Plans for the different buildings or structures may be <br /> combined into a single set of construction documents. <br /> 2. As noted in the Project Description, an existing 1600 square foot building is to be utilized. <br /> The proposed change in use of this building will constitute a change of occupancy. A <br /> change of occupancy will require a code analysis report and necessary plans prepared by <br /> an architect or engineer in accordance with the California Existing Building Code. <br /> Modifications to the existing building shall also include upgrades related to disability access. <br /> The report and plans shall identify existing conditions, propose alterations necessary to <br /> bring the building in compliance with the current code and include the following: <br /> a. Description of proposed use <br /> b. Existing and proposed Occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers (Yes or No) <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC for the new use <br /> j. Occupant load based on the CPC for the new use <br /> k. Risk Category analysis. (Agricultural Buildings are allowed to be constructed to Risk <br /> Category I, whereas other occupancies require Risk Category II or ll.) <br /> 3. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and <br /> finished grade in contour intervals of sufficient clarity to indicate the nature and extent of the <br /> work and show in detail that it complies with the requirements of the code. The plans shall <br /> I Page <br />