My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009999 SSCRPT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WIMER
>
29892
>
2600 - Land Use Program
>
PA-1400049
>
SU0009999 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:34:20 AM
Creation date
9/9/2019 11:07:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0009999
PE
2622
FACILITY_NAME
PA-1400049
STREET_NUMBER
29892
Direction
E
STREET_NAME
WIMER
STREET_TYPE
RD
City
LINDEN
Zip
95236-
APN
06728011
ENTERED_DATE
3/26/2014 12:00:00 AM
SITE_LOCATION
29892 E WIMER RD
RECEIVED_DATE
3/25/2014 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WIMER\29892\PA-1400049\SU0009999\SSCR.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence of �� 1 <br /> buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> There are no storage tanks above ground. There are no above ground fuel tanks on the site. <br /> On-site storm water dissipates through either percolation or evaporation. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Past off-site potential C3 1 <br /> for contamination is low. The subject parcel is located in an agricultural community. J <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Present off-site <br /> potential for contamination is low. There is no knowledge of below ground sources of <br /> contamination in the area of the project site that has or may impact the project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> _ CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> _ 4.1 Evaluation of Each Potential and/or Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth to J <br /> potable ground water in this area is approximately 325 feet. Due to this depth, any pesticides, <br /> insecticides, and fertilizers used on the property in the past or present would have a minimal <br /> impact to the ground water. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers for fuel storage <br /> — tanks on this site; thus the potential for contamination is low. As was stated above, no pesticides, <br /> insecticides, or fertilizers have been used on the site, so based on research reports there is no (5., <br /> potential for contamination to the project site, and no mitigation measures are recommended. <br /> — <br /> 5.2 The Report is Inclusive: All information in this report does not reference any other \/ <br /> s 2J <br /> documents that are not contained in this report. <br /> 5.3 Report was Signed Dated and Stamped: See page 3. (S 3) <br /> 5.4 The Report was Prepared within Six Months of the Date of the Submittal: This report Lf) <br /> was originally generated in March, 2014. J <br /> 5.5 The Attachment/Appendices contain sufficient Documentation to Support Claims <br /> Made in Report: See Appendix. J <br /> _ 2 <br /> YADMD0C\2014\1414\SURFACE AND SUBSURFACE.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.