My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0039434
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1659
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0039434
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 6:01:15 PM
Creation date
9/19/2019 4:37:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0039434
PE
4371
STREET_NUMBER
1659
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206-
APN
16334004
ENTERED_DATE
3/14/2019 12:00:00 AM
SITE_LOCATION
1659 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOUNTING BRACKET UNlSTRUT FOR MOUNTING <br /> TYP RECNTIER(TYP) <br /> 1 AIR—C OLEO, RECTIFIER UNIT <br /> (SEE N07f I &3) <br /> 1"GHS CONOUfr W/(1)— 4 AWG ANODE <br /> AC DISCONNECT SW H HEADER CABLE(BLACK), (1)--#4 AWG <br /> STRUCTURE CABLE(WHITE) <br /> 70 ACPOWERSUPPLY ~+- � J <br /> 3 ANODE JUNCTION 80X <br /> RECTIFIER CABINET 1/2"CRS CONDUIT W/ (SEE(SEE N07£1,) APPROX, <br /> POWER TO EX BRFAKER PANEL SEE DETAIL:�4\ 50• <br /> 14 RERAR fO INCHES APART EX PUMP STATION WALL� PUMP STATION NAME <br /> i FACH WAY& CENTERED IN SLAB <br /> 2 2'CRS CONDUIT W/(2 OR 4 OR 6) <br /> 6 INCH THICK #6 AWG/NALAR HMWPE ANODE CABLES <br /> CONCRETE PAD (BLACK) <br /> a <br /> �\ CITYOF 70CKTON- <br /> 20 1N(ITP) 1"GRS CONDUIT W/(i)—,J4 AWG STRUCTURE PS <br /> RECTIFIER UNIT <br /> CABLE(WHITE),AND (1)—,�B AWG TEST <br /> BOLLARD CABLE(WHITE) <br /> SFE DETAIL j I 30" <br /> CSP__) MIN, <br /> 4 Fr-8 N(TYP) <br /> —TO ANODES <br /> NOTES: --� - <br /> TO PIPELINE <br /> 1. BOLLARDS ARE SHOWN 1N THE CP STATION SITE PLANS, ARE INDICATED AS NEEDED AT EACH SITE. <br /> 2. BOLLARDS SHALL BE INSTALLED WITH SUFFICIENT SPACE FROM THE CABINETS TO ALLOW FULL <br /> OPERATION OF THE CABINET DOORS. <br /> 3. CONCRETE MIX SHALL BE TYPE Il CONCRETE WITH A WATER—TO—CEMENT RATIO BY WEIGHT NOT TO NOTES.- <br /> CONCRETE <br /> OTES <br /> 4. CONCEXCEED .55 AND SHALt RETEE R NFOR NG STEEL SHALLMUM CONFORMToCAS1M A615, GRADE 60 DEFORMED. I. ITHE <br /> I. INSTALL RECTIFIER AND JUNCTION DEILBOX ON THE INTERIOR WALL OF THE PUMP STARON BUILDING. I LETTERING SHALL BEAVED RTA PLATES SHALL BE�f6 G fNCH PIGH WHITE ON INCH TH ICK AND <br /> 5. CONCRETE PAD FINISH SHALL HAVE FINE HAIR LIGHT BROOM FINISH. 2. FOR CABLE TRENCH, SEE DETAIL 2/CP-20, <br /> 3, INSTALL AN AC DISCONNECT SWITCH W/LATCH LOCK ON TUE UMSTRUT ABOVE THE JUNCTION 80X. 2 T/4 PLATES <br /> DIAMETER 8RA55 BOLTED <br /> DL75 THE RECTIFIER CABINET WITH <br /> 1 NEW CONCRETE PAD 2 WALL-MOUNTED INTERIOR RECTIFIERIMCff <br /> CP 19 NOT rD SCALE 3 RECTIFIER 1.D. PLATE <br /> CP—ls NOT To SCALE <br /> CP_19 NOT r0 sCAif <br /> NICKEL PLATED ENGRAVED MICARTA <br /> BRASS HARDWARE e a z s s m ems, g LABEL (�) <br /> COPPER SHORTING ° �° Oa © 0 ® ° <br /> STRAP(5 xl x1/4"rHfCK) ® ®. ® ® ® J4 AWGAHHN ANODE <br /> HEADER CABLE <br /> 0 0 0 0 0 o TO NEW REC7TFIER POSITIVE <br /> 0.001 OHM 25 AMP � ® � <br /> SHUNT(SEE NOTE 1-) J8 AWC THHN TEST CABLE CABLE PERMANENT NYLON <br /> a o ° ° <br /> COPPER LUG(TYP) MARKING TAG _ <br /> RESISTANCE WIRE o <br /> (SEE NOTE 2,) o 0 o ° q <br /> J8 AWG HALAR HMWPE FIBERGLASS JUNCTION BOX — 1 <br /> CABLES FROM ANODES g gAN <br /> (SEE NOTE 1.) FABRIC REINFORCED <br /> _ PHENOLIC PANEL <br /> (1/4"THICK) ABBREWATfONS NUMBER <br /> CABLE IDENTIFICATION(TYP) COVER AN ANODE SEE DETAIL rg\ ANODE NUMBER <br /> {—_{ 1'WS CONDUIT DR — DRAIN CABLE <br /> cP—rn DPL — DISCHARGE PIPELINE <br /> f 2"ORS CONDUIT TT — TEST <br /> 1 MOTES, <br /> 1. SEE TABLE 1 ON SHEET CP—I FOR NUMBER OF ANODES REQUIRED FOR EACH SITE.RESISTANCE W1Rf TO BE INSTALLED BY THE ENGINEER. <br /> 3. IDENTIFY CABLES PER DETAIL 5/CP-19, <br /> 4 ANODE JUNCTION BOX <br /> c�P�19 NOT TO SCALE 5 CABLEIDENTIFICATION <br /> CP— DEPARTMENT OR MUNICIPAL IIRLi19 ND7 TO SCAiF Cr-, F STOC <br /> OKTON,CALIFORNIAFIEs <br /> _ p <br /> _s RECDMMENDEo_ <br /> 'dh corrosion NO REVISIONS RY App pF»'1 ry'+R�p�,pp pqO yo���� c�q®�1�'REPAMS ENONEERINGIgl GER <br /> T�hICPART,jTIIJT,[LS CATKIN(;4Y NN L R 4! II SIUPS"&FQRL.EMAWS CESIGNRD UNDER THE DIRECTION OR <br /> nEr�LtTntrr�Yr "j, � _ - sl-7E_MUD can su pants. in c. <br /> �1�- 3-2Q-2018 ypp9E551 <br /> Snp r100 Willow Pass co��c, I(I(!'�r�������� ����(���5��D �`II MAILS <br /> +nf <br /> S[ock�on,E)A 7-87 V' J PV D L`a TA!LS HO MOHAMMED CLI RATE 0 <br /> PLouc:('-'0'�9J7�700 Concord, 92 94520 I R,COA,E.No.CF 1 L135 REGISTRATION D(PIAES 630-14 s N.CR 1D35 Is <br /> buleaeatumm�sas►�tnxrut Tel. (925)927-6b3a _ DESICN;TDR E,, gzD19 <br /> DATE:DEPARTMENT 5-n r <br /> '— -"--- —` STQClCTU L,CALfFDRAWN:rDH UANTA MUNICIPAL UTILITES DATE:s-a-17 7 Raeeio � <br /> pHEcl«D:nnA, or ceTrF •--„�_. <br /> OF 20 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.