My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
COMPLIANCE INFO 2003 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2019 3:52:53 PM
Creation date
10/21/2019 3:25:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2008
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
206
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-PAGE 2 <br /> WTI, DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISPENSER(S)I S PERFORAIED USING THE FOLLOWING METHODS)(Check all that apply) x1;0. <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSERR CONT`AINIvIE T(UDC) <br /> PANELhG1NUFACTURER: 14 Cede-t' 't• MODEL b: —rL.cJ xts- <br /> LEAK SENSOR(MANUFACTURER: _ �� '}YCl x153• MODEL (s): '154 <br /> - <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ® a.YES ❑ b.NO x155. <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHLTDO WTN? ® a.YES ❑ b.NO x156. <br /> WILL FAILURE-DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a.YES ❑ b.NO <br /> ® 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AATD CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: xus MODEL t(S): <br /> ® 3.VISL'AL MONITORING DONE: ® a.DAILY ❑ b.WEEKLY tRega,.aernCN�y maty Nino. <br /> ❑ 4.NO DISPENSERS <br /> ❑ 99.OTHER(Specify) 1161 <br /> VH. ENHANCED LEAK DETECT Q1�T <br /> ❑ 1.WE HAVE BEEN NOTIFIED BY THE STATE NATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK x1'0 <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN.PER 23 CCR§2644.1,ELD IS PERFORMED EVERY 36 i 10?N-ITIS AS REQUIRED <br /> f_R64a'�Tli�iCi <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY-(Check all that apply) <br /> 1. ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. ® OPERATING MANUALS FOR ELECTRONIC MOIv1TORING EQUIPMENT(Required) <br /> 3. ® THE FAciur 'S BESTMANAGEMENT PRACTICES(Required as of 1101!1005) <br /> 4. ® CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. E(] CALIFORNIA UNDERGROUND STORAGE TAA'K LAW <br /> 6. ® STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MAA'UAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99.❑ OTHER(Specify): <br /> xtst. <br /> Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br /> By January 1,2005 this facility will have a Designated LIST Operator"who has passed the operator exam administered by the International Code Council(ICC). Bf <br /> January 1,2005,and annually thereafter,the "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems. <br /> This training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> A The facility employee's role with regard to the leak detection equipment. <br /> ➢ The facility employee's role with regard to spills and overfills. <br /> ➢ Whom to contact for emergencies and leak detection alarms- <br /> For facility employees hired on or after January 1,2005,the initial training will be conducted within 30 days of the date of hire. <br /> CQMMENT$./ADI'1tTIO IRI.ii�'F`ORMATIO <br /> Please use this section to include any additional UST system monitoring related information(e.g.,additional information required by your local agency): xis5. <br /> c t�� chV�i�-i"i p Yo G-1,®►'l i S Cc* 90% ct-L'd,l b ig% <br /> X. ft EL RESPONSIBILITIES <br /> AS OF 1:1:05,THE"DESIGNATED UST OPERATOR"IDEM-TIFIED IT SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION— <br /> FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br /> EQUIPMENT COVERED BY THIS PLAN,AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br /> UST SYSTEMS IN ACCORDANCE WITH 23 CCR 5 2715(b). <br /> XI. OWINER(OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> OWNER`OPERATORSIGNATU-RE REPRESENTING DATE: Nt"' <br /> ®Owner Nvo. <br /> ❑Operator <br /> OWNER/OPERATOR NAME(print): ` x192' ONNER'OPERATOR TITLE: 14 <br /> j ' <br /> d .,j � cucr)e r— <br /> (Agency Use Only) This plan has been reviewed and: <br /> Approved El Approved With Conditions E]Disapproved <br /> �/`Q <br /> Local Agency Signature: F96 - - Date: <br /> Comments/Special Conditions: <br /> SJCEHD-d(07/03)-314 07/23/03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.