SU0012540
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2900
>
2600 - Land Use Program
>
PA-1800254
>
SU0012540
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2019 9:17:22 AM
Creation date
11/6/2019 9:06:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012540
PE
2631
FACILITY_NAME
PA-1800254
STREET_NUMBER
2900
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205-
APN
14342050, 14342051, 14342053
ENTERED_DATE
9/9/2019 12:00:00 AM
SITE_LOCATION
2900 E FREMONT ST
RECEIVED_DATE
9/6/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
on the Site Plan. All portions of any sign shall be set back a minimum of five (5)feet from any future <br /> right-of-way line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> m. BUILDING CODE REQUIREMENTS: The following California Building Code(CBC)and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection <br /> Division: <br /> 1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with The 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> 3. The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br /> and energy report. <br /> 4. A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading.All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 5. For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC <br /> J. Occupant load based on the CPC <br /> 6. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 7. Accessible routes shall be provided per CBC§ 11 B-206.At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11 B-206.2.1 <br /> PA-1800253 & PA-1800254—Conditions of Approval 3 <br />