My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012521
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SOUTHLAND
>
8080
>
2600 - Land Use Program
>
PA-1900183
>
SU0012521
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2020 12:19:43 AM
Creation date
11/18/2019 1:20:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012521
PE
2690
FACILITY_NAME
PA-1900183
STREET_NUMBER
8080
Direction
E
STREET_NAME
SOUTHLAND
STREET_TYPE
RD
City
MANTECA
Zip
95336-
APN
20809026, 20809027
ENTERED_DATE
9/3/2019 12:00:00 AM
SITE_LOCATION
8080 E SOUTHLAND RD
RECEIVED_DATE
9/3/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6" Pacific Gas and <br /> Electric Company' <br /> Attachment 2—Electric Facilities <br /> It is PG&E's policy to permit certain uses on a case by case basis within its electric <br /> transmission fee strip(s)and/or easement(s)provided such uses and manner in which they are <br /> exercised,will not interfere with PG&E's rights or endanger its facilities.Some <br /> examples/restrictions are as follows: <br /> 1. Buildings and Other Structures: No buildings or other structures including the foot print and <br /> eave of any buildings, swimming pools,wells or similar structures will be permitted within fee <br /> strip(s)and/or easement(s)areas. PG&E's transmission easement shall be designated on <br /> subdivision/parcel maps as"RESTRICTED USE AREA—NO BUILDING." <br /> 2. Grading:Cuts,trenches or excavations may not be made within 25 feet of our towers. <br /> Developers must submit grading plans and site development plans(including geotechnical <br /> reports if applicable),signed and dated,for PG&E's review. PG&E engineers must review grade <br /> changes in the vicinity of our towers. No fills will be allowed which would impair ground-to- <br /> conductor clearances.Towers shall not be left on mounds without adequate road access to <br /> base of tower or structure. <br /> 3. Fences:Walls,fences, and other structures must be installed at locations that do not affect <br /> the safe operation of PG&'s facilities. Heavy equipment access to our facilities must be <br /> maintained at all times. Metal fences are to be grounded to PG&E specifications. No wall,fence <br /> or other like structure is to be installed within 10 feet of tower footings and unrestricted access <br /> must be maintained from a tower structure to the nearest street.Walls,fences and other <br /> structures proposed along or within the fee strip(s)and/or easement(s)will require PG&E <br /> review; submit plans to PG&E Centralized Review Team for review and comment. <br /> 4. Landscaping:Vegetation may be allowed; subject to review of plans. On overhead electric <br /> transmission fee strip(s)and/or easement(s),trees and shrubs are limited to those varieties that <br /> do not exceed 15 feet in height at maturity. PG&E must have access to its facilities at all times, <br /> including access by heavy equipment. No planting is to occur within the footprint of the tower <br /> legs.Greenbelts are encouraged. <br /> 5. Reservoirs, Sumps, Drainage Basins, and Ponds: Prohibited within PG&E's fee strip(s) <br /> and/or easement(s)for electric transmission lines. <br /> 6.Automobile Parking: Short term parking of movable passenger vehicles and light trucks <br /> (pickups,vans, etc.)is allowed. The lighting within these parking areas will need to be reviewed <br /> by PG&E;approval will be on a case by case basis. Heavy equipment access to PG&E facilities <br /> is to be maintained at all times. Parking is to clear PG&E structures by at least 10 feet. <br /> Protection of PG&E facilities from vehicular traffic is to be provided at developer's expense AND <br /> to PG&E specifications. Blocked-up vehicles are not allowed. Carports,canopies,or awnings <br /> are not allowed. <br /> 7. Storage of Flammable, Explosive or Corrosive Materials:There shall be no storage of fuel or <br /> combustibles and no fueling of vehicles within PG&E's easement. No trash bins or incinerators <br /> are allowed. <br /> 8. Streets and Roads:Access to facilities must be maintained at all times.Street lights may be <br /> allowed in the fee strip(s)and/or easement(s)but in all cases must be reviewed by PG&E for <br /> PG&E Gas and Electric Facilities Page 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.