June 19, 2019 M■ SIEGFRIED <br /> VIETNAMESE CATHOLIC CHURCH: BASIS OF DESIGN REPORT <br /> A. SITE CIVIL INFRASTRUCTURE <br /> The following is a general summary of existing and expected onsite wet utility infrastructure <br /> improvements required for the development of the proposed project. We understand the project <br /> generally consists of new buildings and parking facilities on approximately 4.2 acres located at the <br /> northeast corner of the State Highway 99 Frontage Road and Foppiano Lane in Stockton, CA. <br /> 1. Flood Zone: <br /> The proposed project is located within a FEMA FIRM Shaded X flood zone which indicates a flood <br /> depth less than one foot in flood depth for a 100year event.The site also falls within the CVFED <br /> (State) 200 Year Flood Plain with inundation depths ranging from 1 to 3 feet and isolated areas with <br /> 200-year flood depths greater than 3 feet. Building floors with inundation depths greater than 3 feet <br /> require the building finished floors be raised above the flood depths.This issue warrants further <br /> investigation and evaluation of potential solutions outside the scope of this report. <br /> 2. Storm Drain System: <br /> All stormwater runoff generated from the project will be drained using an onsite collection system <br /> and routed to an onsite retention pond in accordance with San Joaquin County Standards. Pond <br /> sizes range depending on the shape of the pond. Preliminarily,the fenced in areas (including 10 foot <br /> perimeter service roads) may include one of the following; <br /> a. 130 ft.x 130 ft. <br /> b. 150 ft.x 115 ft. <br /> c. 180 ft.x 100 ft. <br /> These sizes are based on a 13 foot deep pond (12 foot water depth).This depth may be limited by <br /> the proximity of the sanitary sewer disposal system and could affect the pond size. <br /> 5. Sanitary Sewer: <br /> Offsite sanitary sewer services are not available at this site.The project can be served using an <br /> onsite disposal system consisting of leach lines and leach pits in accordance with San Joaquin County <br /> Standards and substantiated by soils nitrate and percolation testing. Based on the Soil Study <br /> provided by Terracon,this site will require seepage pits or an alternative method of sewage <br /> disposal. <br /> Based on San Joaquin County Environmental Health Standards, a church/hall with a kitchen and an <br /> occupancy of 400 people,the system must provide a capacity of 4,000 gallons per day.This system <br /> will include septic tank(s)with at least a 4,200 gallon capacity.The combination leach field and <br /> Stockton San Jose Sacramento Modesto <br /> 3244 Brookside Rd.,#100 111 N. Market St.,#300 109 Scripps Drive 100 Sycamore Ave,#100 <br /> Stockton,CA 95219 San Jose,CA 95113 Sacramento, CA 95825 Modesto,CA 95354 <br /> t:209.943.2021 t:408.754.2021 t:916.520.2777 t:209.762.3580 <br />