SU0012637
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SARGENT
>
15737
>
2600 - Land Use Program
>
PA-1900129
>
SU0012637
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2019 2:16:33 PM
Creation date
11/19/2019 9:03:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012637
PE
2626
FACILITY_NAME
PA-1900129
STREET_NUMBER
15737
Direction
E
STREET_NAME
SARGENT
STREET_TYPE
RD
City
LODI
Zip
95240-
APN
05307006, 05307007, 05307008
ENTERED_DATE
11/14/2019 12:00:00 AM
SITE_LOCATION
15737 E SARGENT RD
RECEIVED_DATE
11/8/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 9-1015.9) <br /> 3. Each parking stall shall be an unobstructed rectangle, minimum nine (9) feet wide and <br /> twenty (20) feet long. (Development Title Section 9-1015.5[b]) <br /> e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on <br /> the Site Plan: <br /> 1. Access driveways shall have a width of no less than twenty-five (25) feet for two-way <br /> aisles and sixteen (16) feet for one-way aisles, except that in no case shall driveways <br /> designated as fire department access be less than twenty (20) feet wide. (Development <br /> Title Section 9-1015.5[h][1]) <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1. If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> g. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and <br /> be included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) <br /> feet from any future right-of-way line, including any corner cut-off(snipe). (Development Title <br /> Section 9-1710.2[g]) <br /> h. ANIMAL REGULATIONS: The following animal regulations apply and shall be provided: <br /> 1. All animal enclosures, including but not limited to pens, cages, and feed areas, shall be <br /> maintained free from litter, garbage, and excessive accumulation of manure, so as to <br /> discourage the proliferation of flies, other disease vectors, and offensive odors. Premises <br /> shall be maintained in a neat and sanitary manner. (Development Title Section 9- <br /> 1045.4[b]) <br /> 2. Except for movement on and off the property, animals shall not be kept or maintained in <br /> coops, pens, corrals, or within barns or similar structures, closer than 40 feet from any <br /> rear or side property line. (Development Title Section 9-1045.3) <br /> i. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and <br /> San Joaquin County Ordinance requirements will be applicable to the proposed project. <br /> The following conditions shall be addressed prior to submittal of a building permit <br /> application to the Building Inspection Division: <br /> 1. The Project Description to establish a commercial stable proposes to use all existing <br /> buildings. The approved use of the existing buildings was for agricultural use. The <br /> proposed change in use from agricultural to commercial use will constitute a change of <br /> occupancy. A change of occupancy will require a code analysis report and necessary <br /> plans prepared by an architect or engineer in accordance with the California Existing <br /> Building Code. The report and plans shall identify existing conditions, propose alterations <br /> necessary to bring the building in compliance with the current code and include the <br /> following: <br /> A. Description of proposed use <br /> B. Existing and proposed Occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No) <br /> E. Number of stories <br /> Planning Commission Staff Report, Item #2 12/19/2019 — PA-1900129 (UP) 3 <br /> Conditions of ADoroval <br />
The URL can be used to link to this page
Your browser does not support the video tag.