Laserfiche WebLink
4. A soils report is required pursuant to Section 1803 for foundations and CBC appendix Section <br /> J104 for grading of the CBC. All recommendations of the Soils Report shall be incorporated <br /> into the construction drawings. <br /> 5. For each proposed building, provide the following information on the plans: <br /> A. Description of proposed use. <br /> B. Existing and proposed Occupancy Groups. <br /> C. Type of construction. <br /> D. Sprinklers (Yes or No). <br /> E. Number of stories. <br /> F. Building height. <br /> G. Allowable floor area <br /> H. Proposed floor area.. <br /> I. Occupant load based on the CBC. <br /> J. Occupant load based on the CPC. <br /> 6. The proposed conversion of the existing building to a new use will constitute a change of <br /> occupancy. A change of occupancy will require a code analysis report and necessary plans <br /> prepared by an architect or engineer in accordance with the California Existing Building Code. <br /> The report and plans shall identify existing conditions, propose alterations necessary to bring <br /> the building in compliance with the current code and include the following <br /> A. Description of proposed use. <br /> B. Existing and proposed Occupancy Groups. <br /> C. Type of construction. <br /> D. Sprinklers (Yes or No). <br /> E. Number of stories. <br /> F. Building height. <br /> G. Allowable floor area. <br /> H. Proposed floor area. <br /> I. Occupant load based on the CBC for the new use. <br /> J. Occupant load based on the CPC for the new use. <br /> K. Risk Category analysis. (Agricultural Buildings are allowed to be constructed to Risk <br /> Category I, whereas other occupancies require Risk Category II or Il.) <br /> Modifications to existing buildings are required to include upgrades related to disability access <br /> pursuant to the California Existing Building Code. Plans showing these upgrades must be <br /> prepared by a registered engineer or licensed architect and shall be submitted for <br /> 7. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 8. Accessible routes shall be provided per CBC Section 11 B-206. At least one accessible route <br /> shall be provided within the site from accessible parking spaces and accessible passenger <br /> loading zones; public streets and sidewalks; and public transportation stops to the accessible <br /> building or facility entrance they serve. Where more than one route is provided, all routes must <br /> be accessible. §11 B-206.2.1 <br /> 9. At least one accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> 10. At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> PA-1900082 and PA-1900083—Conditions of Approval 4 <br />