4. A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading.All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 5. For each proposed new buildings, provide the following information for the plan: <br /> A. Description of proposed use. <br /> B. Existing and proposed occupancy groups. <br /> C. Type of Construction. <br /> D. Sprinklers (Yes or No). <br /> E. Number of stories. <br /> F. Buildable height. <br /> G. Allowable floor area. <br /> H. Proposed floor area. <br /> I. Occupant load based on the CBC. <br /> J. Occupant load based on the CPC. <br /> 6. Accessible routes shall be provided per CBC§ 11 B-206.At least one(1)accessible route shall <br /> be provided within the site from accessible parking spaces and accessible passenger loading <br /> zones; public streets and sidewalks; and public transportation stops to the accessible building <br /> or facility entrance they serve. Where more than one (1) route is provided, all routes must be <br /> accessible. § 11 B-206.2.1 <br /> 7. At least one (1) accessible route shall connect accessible buildings, accessible facilities, <br /> accessible elements and accessible spaces that are on the same site. § 11 B-206.2.2 <br /> 8. At least one (1) accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which are <br /> otherwise connected by a circulation path. § 11 B-206.2.4 <br /> 9. Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that these accessible parking spaces are <br /> required for each phase of the project. These parking space(s) shall be located as close as <br /> possible to the primary entrance to the building. <br /> 10. Adequate sanitary facilities shall be provided for employees and customers, per the <br /> requirements of Chapter 4 of the California Plumbing Code. <br /> 11. This project will be required to comply with the Model Water Efficient Landscape ordinance <br /> requirements of the California Code of Regulations, Title 22, Division 2, Chapter 2.7 <br /> I. FIRE CODE REQUIREMENTS: The following California Fire Code (CFC) requirements will be <br /> applicable to the proposed project. The following conditions shall be addressed prior to submittal <br /> of a building permit application to the Building Inspection Division. <br /> 1. CFC 507 Fire Protection Water Supply — Fire flow and hydrants shall be provided for the <br /> proposed project by the use of: CFC Appendix B. Including on-site fire hydrants. <br /> 2. If Fire Protection Systems are required they shall be installed according to the CFC, Chapter 9 <br /> and the appropriate standards and guides adopted in Chapter 35 of the California Building <br /> Code and the California Electrical Code. <br /> 3. CFC, Section 503 Fire Apparatus Access Roads—Shall be provided as required by this section. <br /> 4. CFC, Section 906 Portable Fire Extinguishers—Provide portable fire extinguishers as required <br /> PA-1900201 —Conditions of Approval 4 <br />