My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> i <br /> i <br /> i <br /> D. Results of TestingfServicin ' <br /> Software Version Installed; <br /> Complete the following checklist: I <br /> X Yes tl No' Is the audible alarm operational? <br /> X Yes n No' Is the visual alarm operational? <br /> I <br /> X Yes I.) No' Were all sensors visually Inspected,functionally tested,and confirmed operational? <br /> X Yes n No` Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment will not Interfere with their <br /> ro er o erasion? <br /> X Yes o No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? I <br /> X WA I ! <br /> X Yes O No' For pressurized piping systems, does the turbine automatically shut down If the piping secondary containment monitoring system <br /> WA detects a leak,falls to operate,or is electrically disconnected? If yes:which sensors Initiate positive shut-down? (Check all that apply) <br /> X Sump[Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> faflure/disconnection? X Yes; n No. <br /> X Yes n No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(I.e.no mechanical overfill prevention <br /> NIA valve is installed),Is the overfill warning alarm visible and audible at the tank fill polnt(s)and operating property? If so,at what percent <br /> of tank capacity does the alarm trigger? 95 % <br /> X No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> Yes' manufacturer name and model for all replacement parts In Section E below. <br /> X Yes' No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)D Product, X Water. If <br /> es descr be causes In Section E below. <br /> X Yes U No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> X Yes n No' Is all monitoring equipment operational per manufacturer's specifications? <br /> i <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: _REMOVED WATER FROM ALL SUMPS THAT HAD <br /> WATER. _ 1 <br /> _ I <br /> I <br /> _ I <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/2 1/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.