My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 2:36:09 PM
Creation date
11/19/2019 2:48:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I� <br /> F. In.-Tank Gauging/SIR Equipment: X Check this box If tank gauging Is used only for inventory control. <br /> L- Check this box If no lank gauging or SIR equipment is installed. <br /> This section must be completed if In-tank gauging equipment Is used to perform leak detection monitoring. <br /> Com lite the following checklist: <br /> X Yes :7 No' Has all Input wiring been Inspected for proper entry and termination,Including testing for ground faults? <br /> X Yes a No' Were all tank gauging probes visually inspected for damage and residue buildup? <br /> X YEis D No' Was accuracy of system product level readings tested? <br /> X Yes D No' Was accuracy of system water level readings tested? <br /> X Yes o No' Were all probes relnstatled property? j <br /> X Yes 0 No' I Were all items on the equipment manufacturer's maintenance checklist completed? 1i <br /> In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors(LLD): u Check this box if LLDs are not installed. <br /> i <br /> Com lite the following checklist: <br /> I <br /> X Ye!s D No' For equipment start-up or annual equipment certification,was a leak simulated to verity LLD performance?(Check aN <br /> n N/A that apply) Simulated leak rate: X 3 g.p.h.; U 0.1 g.p,h; r,0.2 g.p.h, j <br /> i <br /> X Yes ❑ No' Were all LLDs confirmed operaflonal and accurate within regulatory requirements? <br /> X Yes D No' Was the testing apparatus property calibrated? <br /> Yes o No' For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> X NIA <br /> X Yr:s D No' For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? II! <br /> N/A ' <br /> X Yes o No' For electronic LLDs, does the turbine automatically shut off If any portion of the monitoring system is disabled or <br /> N/A disconnected? <br /> X Yes 1_; No' For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or i <br /> N/A falls a teat? ` <br /> X Yes C No' For electronic LLDs,have all accessible wiring connections been visually Inspected? <br /> N/A <br /> X Yos C No' Were all items on the equipment manufacturer's maintenance checklist completed? <br /> In the Section H,below,describe how and when these deficiencies were or will be corrected. I <br /> H. Comments: <br /> i <br /> i <br /> — I <br /> E <br /> 1 <br /> j <br /> — I <br /> — E <br /> j <br /> Monitoring System Certification Page 3 of 4 12107 <br /> 3 2/21/07 <br /> I <br /> i <br /> s <br />
The URL can be used to link to this page
Your browser does not support the video tag.