My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
COMPLIANCE INFO_2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 3:47:04 PM
Creation date
11/26/2019 9:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3,Title 23,California Code of <br /> Regulations <br /> This forth must be used to document testing and servicing of monitoring equipment A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> Name: DELTA ARCO Bldg.No.: <br /> Site <br /> Address: 440 W CHARTER WAY City: STOCKTON Zip: 96206 <br /> Facility Contact <br /> Person: MAJOR Contact Phone No.: (209)465.2487 <br /> MakelModel of Monitoring System: VEEDER ROOT 360 Date of Testing/Servicing: 08-29-18 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicatespecific equipment Ins ectad/serviced: <br /> TanklD: 87 TanklD: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor, Model: 420 ® Annular Space or Vault Sensor. Model: 420 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> D Fill Sump Sensor(s). Model: D Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> D Electronic Line Leak Detector. Model: D Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: FLAPPER ® Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> D Other(specify equipment type and model in Section E on Page 2). D Other(specify equipment type and model in Section E on Page 2), <br /> TanklD: TanklD: <br /> D In-Tank Gauging Probe. Model: D In-Tank Gauging Probe. Model: <br /> D Annular Space or Vault Sensor. Model: D Annular Space or Vault Sensor. Model: <br /> D Piping Sump/Trench Sensor(s). Model: D Piping Sump/Trench Sensor(s). Model: <br /> D FIII Sump Sensor(s). Model: D Fill Sump Sansone). Model: <br /> D Mechanical Line Leak Detector. Model: D Mechanical Line Leak Detector. Model: <br /> D Electronic Line Leak Detector. Model: D Electronic Line Leak Detector. Model: <br /> D Tank Overfill/High-Level Sensor. Model: D Tank Overfill/High-Level Sensor. Model: <br /> D Other(specify equipment type and model in Section E on Page 2). D Other(specify equipment type and model in Section E on Page 2). <br /> DlspenserlD: 1-2 Dispenser ID: 3-4 <br /> ® Dispenser Containment Senscr(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> D Dispenser Containment Float(s)and Chain(s). D Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5.6 DlspenserlD: 7-8 <br /> ® Dispenser Containment Sensor(s). Mods- 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> D Dispenser Containment Float(s)and Chain(s). D Dispenser Containment Flost(s)and Cham(s), <br /> DlspenserlD: 9.10 DlspenserlD: 11-12 <br /> ® Dispenser Containment <br /> ® Dispenser Containment Sensor(s). Model: 208 Sensor(s). Model: 208 <br /> IN Shearvalve(s). ®Shear Valve(s). <br /> D Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Floats)and Chain(s). <br /> •If the facility contains more tanks or dispensers,copy this form. Include Information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification Is Information(e.g.manufacturers'checklists)necessary to verify that this Information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®system set-up Z Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: /- - <br /> Certification No.: 8883072-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n0 STREET GALT,CA 95632 Date of Testing/Servicing: 08-29-18 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.