Laserfiche WebLink
SECTION 7 <br /> SMITH <br /> TESTING RECOMMENDATIONS <br /> READ THIS CAREFULLY <br /> 1.7.1 Safety precautions occur while testing fiberglass Locate pressure gauge in close <br /> SMITH FIBERGLASS PRODUCTS pipe with air or gas, the system proximity to the pressurizing <br /> SHALL NOT BE LIABLE UNDER would be subject to considera- equipment—not directly on the <br /> ANY WARRANTY, CONTRACT, ble whipping and other shock- piping system. Pressure gauge <br /> OR IN TORT, FOR ANY RESULT- induced conditions due to the with the test pressure at midscale <br /> INGINJURYTOPERSONNEL OR sudden release of stored energy. is recommended. <br /> DAMAGE TO EQUIPMENT, PIPE, The violent release can cause The normal recommended <br /> OR OTHER PERSONAL PROP- severe personal injury or death procedure is to conduct a <br /> ERTY FOR FAILURE TO FOLLOW to personnel in the area and can hydrostatic cyclic pressure test. <br /> THE PROCEDURES AND also cause property damage to The piping system is subjected to <br /> COMPLY WITH THE PRECAU- the pipe or other property. 10 pressurization cycles at 1112 <br /> TIONS SET FORTH. If a line is tested with air or gas, times the anticipated or design <br /> As in any system where Smith Fiberglass Products will operating pressure. Note: For low <br /> A\ <br /> pressure is employed, not be responsible for any result- pressure applications, it is best to <br /> ing injury to personnel or dam- use the pressure rating of the <br /> adequate safety precautions age to property, including the pipe as the design operating <br /> should exercised. EXERCISE pipe. If there is no alternative to pressure, i.e. test at 1112 times the <br /> DUE CARE IN INSTALLING AND testing with air or gas, Smith cyclic rating. The test pressure <br /> TESTING THE PIPING SYSTEM. Fiberglass Products will recom- should not exceed 11/2 times the <br /> DON'T ASSUME THE RISK OF mend test procedures and pre- maximum rated operating pres- <br /> INJURY OR PROPERTY DAMAGE. cautions to minimize possible sure for the lowest rated ele- <br /> hazards, but will not bear ment in the system. Pressure is <br /> In buried applications, it is sug- responsibility for damage or then kept on the system for 1-8 <br /> gested that long pipe runs be par- injury under any circumstances. hours while the line is inspected <br /> tially backfilled at various points Such testing is done entirely at for leaks. <br /> to secure them in place.All joints the risk of those involved. <br /> and connections should be left 1.7.3 Air test procedures and <br /> exposed for inspection. 1.7.2 Test procedures safety precautionslll <br /> SMITH FIBERGLASS PRO- Installed Smith Fiberglass Pro-' TESTING WITH AIR OR DUCTS RECOMMENDS ducts pipe systems should be ' GAS IS EXTREMELY <br /> THAT YOU DO NOT TEST ANY tested prior to use to assure DANGEROUS AND SHOULD <br /> INSTALLATION WITH AIR OR soundness of all joints and con- NOT BE DONE. CONSULT <br /> GAS BECAUSE OF THE SAFETY nections. In testing,sudden pres- YOUR SMITH FIBERGLASS <br /> HAZARDS CREATED. The light sure surges or "water hammer" PRODUCTS REPRESENTATIVE <br /> weight, flexibility, and elasticity must be avoided, as in some OR CALL SMITH FIBERGLASS <br /> of fiberglass pipe create different instances surge or hammer can PRODUCTS AT (501) 568-4010 <br /> conditions than are present with produce pressures of several times IF YOU CONTEMPLATE EX- <br /> steel pipe. if a failure should the rating of the pipe and fittings. CEEDING THE RECOMMENDED <br /> (1)Do not use these testing procedures and safely precautions for Smith Fiberglass Products secondary containment piping system. <br /> See Part Two,Section 8 of this manual for testing procedures for secondary containment piping systems. <br /> 19 <br />