Laserfiche WebLink
! LDT 880 - LEAK DETECTOR CHECKLIST <br /> CONTRACTOR CUSTOMER <br /> R . J . MYERS & SONS , INC . TEXACO 276 <br /> DATE PRODUCT LOCATION <br /> 4/29/92 UNL PLUS 440 W . CHARTER WAY <br /> TECHNICIAN J . SHINE STOCKTON , CA <br /> T SUBMERSIBLE PUMP IDENTIFICATION <br /> I <br /> CHECK MFG. RECORD SERIAL # 55037256 <br /> INDICATE MODEL NO. IF KNOWN <br /> RED TOKHEIM GILBARCO BENNETT DRESSER A.O.SMITH BOWSER SOUTH OTHER <br /> I JACKET WAYNE KEENE WEST <br /> X <br /> I <br /> II LEAK DETECTOR IDENTIFICATION <br /> CHECK TYPE DATE 1/3/84 S/ N 8554 <br /> RED JACKET RED JACKET RED JACKET TOKHEIM OTHER <br /> MODEL 116-030LMODEL 116-017 X MODEL 116-011 A MODEL 585PM <br /> PLD-2SEC DLD 2SEC DLD SSEC DLD 2SEC <br /> HEX HEAD HEX HEAD ROUND HEAD SQUARE HEAb"' <br /> ' PRE-TEST CONDITIONS <br /> VOLUME OF PRODUCT FLUSHED THRU LINE GALLONS <br /> OTHER COMMENTS <br /> - TEST PROCEDURE <br /> LEAK DETECTOR INSTALLED LEAK DETECTOR ISOLATED <br /> TEST AT DISPENSER FROM PRODUCT LINE-TEST AT PUMP PIT <br /> REFER TO LDT INSTRUCTIONS <br /> III GENERAL UNE AND PUMP INFORMATION III GENERAL PUMP INFORMATION <br /> RECORD OPERATING PUMP PRESSURE 29 prig. FLUSH LOT TESTOR <br /> i AIR-VAPOR TEST WITH PUMP OFF MEASURE RECORD OPERATING PUMP PRESSURE prig. <br /> AND RECORD 75 ML <br /> IV PRESSURE STEP TEST IV PRESSURE STEP TEST-SUBMERSIBLE PUMP <br /> REMAINS ON THRU-OUT TEST PROCEDURE <br /> WITH BOTTOM SELECTOR IN PRESSURE STEP TEST WITH BOTTOM SELECTOR IN PRESSURE STEP TEST <br /> POSITION TURN ON PUMP POSITION ROTATE ISOLATOR FULLY(CCNV) <br /> RECORD TIME IN SECONDS GUAGE RECORD TIME IN SECONDS GUAGE <br /> NEEDLE REMAINS IN COLORED ZONE 2 SEC. NEEDLE REMAINS IN COLORED ZONE SEC: <br /> V 3 GALLON PER HOUR LEAK SIMULATED TEST V 3 GALLON PER HOUR LEAK SIMULATED TEST <br /> 1 WITH BOTTOM SELECTOR IN 3 GPHWITH BOTTOM SELECTOR IN 3 GPH TEST POSITION <br /> 1 <br /> A) MEASURE AND RECORD VOLUME IN� A) MEASURE AND RECORD VOLUME IN <br /> CALIBRATED BEAKER FOR 60 SECOND TEST LEAK ML CALIBRATED BEAKER FOR 60 SECOND TEST ML <br /> B) OPEN DISPENSER NOZZLE OR PLACE BOTTOM B) PLACE BOTTOM SELECTOR IN DISPENSER <br /> SELECTOR IN DISPENSER NOZZLE POSITION. NOZZLE POSITION. <br /> FLOW RATE OF APPROX.11h3GAL PER MINUTE FLOW RATE OF APPROX.1123GAL PER MINUTE <br /> WILL BE OBSERVED. WILL BE OBSERVED. <br /> DOES GUAGE NEEDLE MOVE TO LOWER DOES GUAGE NEEDLE MOVE TO LOWER <br /> END OF COLORED ZONE YES NO X END OF COLORED ZONE YES NO <br /> DOES FLOW RATE INCREASE TO APPROX. DOES FLOW RATE INCREASE TO APPROX. <br /> 11h3GAL PER MINUTE YES NO__�L 11/2-3GAL PER MINUTE YES-NO- <br /> C) <br /> ESNOC) CLOSE DISPENSER NOZZLE OR PLACE BOTTOM C) PLACE BOTTOM SELECTOR IN <br /> SELECTOR IN 3GPH TEST POSITION: 3GPH TEST POSITION: <br /> GUAGE RETURN TO COLORED GUAGE RETURN TO COLORED <br /> ZONE YES NO X ZONE YES NO <br /> GUAGE DOES NOT RETURN TO GUAGE DOES NOT RETURN TO <br /> COLORED ZONE YES X NO COLORED ZONE YES NO <br /> GAUGE GOES TO OPERATING X GAUGE GOES TO OPERATING <br /> PRESSURE YES NO PRESSURE YES NO <br /> LEAK DETECTOR TEST PASS •/ LEAK DETECTOR TEST PASS <br /> FAIL X FAIL <br /> • PURPORANMORLESS FORId 680A 0 <br />