Laserfiche WebLink
{ LDT 880 - LEAK DETECTOR CHECKLIST <br /> CONTRACTOR CUSTOMER <br /> R . J . MYERS & SONS , INC . TEXACO 276 <br /> GATE T <br /> RODUCT LOCATION . <br /> 4/29/ 92 UNL PLUS 440 W . CHARTER WAY <br /> TECHNICIAN <br /> J . SHINE STOCKTON , CA <br /> I SUBMERSIBLE PUMP IDENTIFICATION <br /> CHECK MFG. RECORD SERIAL # 55037256 <br /> INDICATE MODEL NO. IF KNOWN <br /> RED TOKHEIM GILBARCO BENNETT DRESSER AOSMITH BOWSER SOUTH OTHER <br /> . . <br /> JACKET WAYNE KEENE WEST <br /> X <br /> II LEAK DETECTOR IDENTIFICATION <br /> CHECK TYPE DATE 3/2/92 S/N 8009 <br /> RED JACKET RED JACKET RED JACKET TOKHEIM OTHER <br /> MODEL 116-030MODEL 116-017 MODEL 116-011A MODEL 585PM R.J. XLD X <br /> PLD-2SECL DLD 2SEC DLD SSEC DLD 2SEC <br /> HEX HEAD HEX HEAD ROUND HEAD SQUARE HEAb"' 116-076 <br /> PRE-TEST CONDITIONS <br /> VOLUME OF PRODUCT FLUSHED THRU LINE GALLONS <br /> OTHER COMMENTS <br /> TEST PROCEDURE <br /> LEAK DETECTOR INSTALLED LEAK DETECTOR ISOLATED <br /> TEST AT DISPENSER FROM PRODUCT LINE-TEST AT PUMP PIT <br /> 7 REFER TO LDT INSTRUCTIONS <br /> I. III GENERAL LINE AND PUMP INFORMATION III GENERAL PUMP INFORMATION <br /> RECORD OPERATING PUMP PRESSURE 29 psig. FLUSH LDT TESTOR <br /> AIR-VAPOR TEST WITH PUMP OFF MEASURE 75 RECORD OPERATING PUMP PRESSURE prig. <br /> 1 ANO RECORD ML <br /> IV PRESSURE STEP TEST IV PRESSURE STEP TEST-SUBMERS(BLE PUMP <br /> REMAINS ON THRU-OUT TEST PROCEDURE <br /> WITH BOTTOM SELECTOR IN PRESSURE STEP TEST WITH BOTTOM SELECTOR IN PRESSURE STEP TEST <br /> POSITION TURN ON PUMP POSITION ROTATE ISOLATOR FULLY(CCMQ <br /> RECORD TIME IN SECONDS GUAGE 2 RECORD TIME IN SECONDS GUAGE <br /> NEEDLE REMAINS IN COLORED ZONE SEC. NEEDLE REMAINS IN COLORED ZONE SEC: <br /> II V 3 GALLON PER HOUR LEAK SIMULATED TEST V 3 GALLON PER HOUR LEAK SIMULATED TEST <br /> WITH BOTTOM SELECTOR IN 3 GPH TEST POSITION WITH BOTTOM SELECTOR IN 3 GPH TEST POSITION <br /> A) MEASURE AND RECORD VOLUME IN A) MEASURE AND RECORD VOLUME IN <br /> CALIBRATED BEAKER FOR 60 SECOND TEST 2 5 5 ML CALIBRATED BEAKER FOR 60 SECOND TEST ML <br /> B) OPEN DISPENSER NOZZLE OR PLACE BOTTOM B) PLACE BOTTOM SELECTOR IN DISPENSER <br /> SELECTOR IN DISPENSER NOZZLE POSITION. NOZZLE POSITION. <br /> FLOW RATE OF APPROX.1'h3GAL PER MINUTE FLOW RATE OF APPROX.1123GAL PER MINUTE <br /> WILL BE OBSERVED. WILL BE OBSERVED. <br /> DOES GUAGE NEEDLE MOVE TO LOWER DOES GUAGE NEEDLE MOVE TO LOWER <br /> END OF COLORED ZONE YES_X__NO END OF COLORED ZONE YES NO <br /> DOES FLOW RATE INCREASE TO APPROX. DOES FLOW RATE INCREASE TO APPROX. <br /> 1'h3GAL PER MINUTE YES X NO 11123GAL PER MINUTE YES NO <br /> C) CLOSE DISPENSER NOZZLE OR PLACE BOTTOM C) PLACE BOTTOM SELECTOR IN <br /> SELECTOR IN 3GPH TEST POSITION: 3GPH TEST POSITION: <br /> GUAGE RETURN TO COLORED GUAGE RETURN TO COLORED <br /> ZONE YES X NO ZONE YES NC <br /> GUAGE DOES NOT RETURN TO X GUAGE DOES NOT RETURN TO <br /> COLORED ZONE YES NO COLORED ZONE YES NO <br /> GAUGE GOES TO OPERATING X GAUGE GOES TO OPERATING <br /> PRESSURE YES NO PRESSURE YES NO <br /> LEAK DETECTOR TEST PFAfLX LEAK DETECTOR TEST PASS <br /> FA(L <br /> PURPORAVAPORLESS FORM 6E0A 0 <br />