LDT 880 - LEAK DETECTOR CHECKLIST <br /> CONTRACTOR CUSTOMER <br /> R . J . MYERS & SONS , INC . TEXACO 276 c <br /> DATE PRODUCTS! LOCATION <br /> 4/29/92 DIEL 440 W . CHARTER WAY <br /> TECHNICIAN J . SHINE STOCKTON , CA <br /> I SUBMERSIBLE PUMP IDENTIFICATION <br /> i <br /> CHECK MFG. RECORD SERIAL # 55037248 <br /> INDICATE MODEL NO. IF KNOWN <br /> RED TOKHEIM GILBARCO BENNETT DRESSER A.O.SMITH BOWSER SOUTH OTHER <br /> I JACKET WAYNE KEENE WEST <br /> X <br /> I <br /> II LEAK DETECTOR IDENTIFICATION <br /> CHECK TYPE DATE 1/9/90 S/N 6049 <br /> RED JACKET RED JACKET RED JACKET TOKHEIM OTHER <br /> MODEL 116-030 MODEL 116-017MODEL 116-011 A MODEL 585PM <br /> PLD-2SEC DLD 2SEC X DLD 5SEC DLD 2SEC <br /> HEX HEAD HEX HEAD ROUND HEAD SQUARE HEAb <br /> PRE-TEST CONDITIONS <br /> VOLUME OF PRODUCT FLUSHED THRU LINE GALLONS <br /> OTHER COMMENTS <br /> 1 - TEST PROCEDURE <br /> LEAK DETECTOR INSTALLED LEAK DETECTOR ISOLATED <br />! TEST AT DISPENSER FROM PRODUCT UNE-TEST AT PUMP PIT <br /> REFER TO LDT INSTRUCTIONS <br /> .I. III GENERAL LINE AND PUMP INFORMATION III GENERAL PUMP INFORMATION <br /> RECORD OPERATING PUMP PRESSURE 29 prig. FLUSH LOT TESTOR <br /> AND R ECOR TDEST WITH PUMP OFF MEASURE Q_ML RECORD OPERATING PUMP PRESSURE prig. <br /> IV PRESSURE STEP TEST IV PRESSURE STEP TEST-SUBMERSIBLE PUMP <br /> REMAINS ON THRU-0UT TEST PROCEDURE <br /> WITH BOTTOM SELECTOR IN PRESSURE STEP TEST WITH BOTTOM SELECTOR IN PRESSURE STEP TEST <br /> POSITION TURN ON PUMP POSITION ROTATE ISOLATOR FULLY(CCAV) <br /> RECORD TIME IN SECONDS GUAGE RECORD TIME IN SECONDS GUAGE <br /> NEEDLE REMAINS IN COLORED ZONE 2 , SEC. NEEDLE REMAINS IN COLORED ZONE SEC: <br /> 'I V 3 GALLON PER HOUR LEAK SIMULATED TEST V 3 GALLON PER HOUR LEAK SIMULATED TEST <br /> WITH BOTTOM SELECTOR IN 3 GPH TEST POSITION WITH BOTTOM SELECTOR IN 3 GP"TEST POSITION <br /> A) MEASURE AND RECORD VOLUME IN A) MEASURE AND RECORD VOLUME IN <br /> CALIBRATED BEAKER FOR 60 SECOND TEST 250 ML CALIBRATED BEAKER FOR 60 SECOND TEST ML <br /> B) OPEN DISPENSER NOZZLE OR PLACE BOTTOM B) PLACE BOTTOM SELECTOR IN DISPENSER <br /> SELECTOR IN DISPENSER NOZZLE POSITION. NOZZLE POSITION. <br /> FLOW RATE OF APPROX.1'h3GAL PER MINUTE FLOW RATE OF APPROX.1123GAL PER MINUTE <br /> WILL BE OBSERVED. WILL BE OBSERVED_ <br /> DOES GUAGE NEEDLE MOVE TO LOWER DOES GUAGE NEEDLE MOVE TO LOWER <br /> END OF COLORED ZONE YES__L__NO ENO OF COLORED ZONE YES NO <br /> DOES FLOW RATE INCREASE TO APPROX. X DOES FLOW RATE INCREASE TO APPROX. <br /> V/23GAL PER MINUTE YES NO 11123GAL PER MINUTE YES NO <br /> C) CLOSE DISPENSER NOZZLE OR PLACE BOTTOM C) PLACE BOTTOM SELECTOR IN <br /> SELECTOR IN 3GPH TEST POSITION: 3GPH TEST POSITION: <br /> GUAGE RETURN TO COLORED GUAGE RETURN TO COLORED <br /> ZONE YES X NO ZONE YES-NO- <br /> GUAGE <br /> ESNOGUAGE DOES NOT RETURN TO GUAGE DOES NOT RETURN TO <br /> COLORED ZONE YES NO X COLORED ZONE YES NO <br /> GAUGE GOES TO OPERATING GAUGE GOES TO OPERATING <br /> PRESSURE YES-NO, X PRESSURE YES NO <br /> LEAK DETECTOR TEST PASSLEAK DETECTOR TEST PASS <br /> FAILH FAIL <br /> • PURPORANAPORLESS FORM 680A O <br /> 1 <br />