Laserfiche WebLink
LDT 880 - LEAK DETECTOR CHECKLIST <br /> CONTRACTOR CUSTOMER - <br /> •R . J . IdYERS & SONS , INC . TEXACO 276 <br /> DATE PRODUCT LOCATION <br /> 4/29/92 SUPER 440 W . CHARTER <br /> TECHNICIAN J . SHINE STOCKTON , CA <br /> I SUBMERSIBLE PUMP IDENTIFICATION <br /> CHECK MFG. <br /> INDICATE MODEL NO. IF KNOWN RECORD SERIAL # 55037247 <br /> RED TOKHEIM GILBARCO BENNETT DRESSER A.O.SMITH BOWSER SOUTH OTHER <br /> JACKET WAYNE KEENE WEST <br /> j X <br /> II LEAK DETECTOR IDENTIFICATION <br /> CHECK TYPE DATE 10/4/91 S/N 5150 <br /> RED JACKET RED JACKET RED JACKET TOKHEIM OTHER <br /> MODEL 116-030MODEL 116-017Lx <br /> MODEL 116-011 A MODEL 585PM <br /> PLD-2SECL DLD 2SEC DLD SSEC DLD 2SEC . 'L <br /> HEX HEAD HEX HEAD ROUND HEAD SQUARE HEAd"' <br /> 1 PRE-TEST CONDITIONS <br /> VOLUME OF PRODUCT FLUSHED THRU LINE GALLONS <br /> OTHER COMMENTS <br /> t <br /> TEST PROCEDURE <br /> LEAK DETECTOR INSTALLED LEAK DETECTOR ISOLATED <br /> i <br /> TEST AT DISPENSER FROM PRODUCT LINE-TEST AT PUMP PIT <br /> j REFER TO LDT INSTRUCTIONS <br /> III GENERAL LINE AND PUMP INFORMATION III GENERAL PUMP INFORMATION <br /> RECORD OPERATING PUMP PRESSURE 30 prig. FLUSH LDT TESTOR <br /> AIR-VAPOR TEST WITH PUMP OFF MEASURE RECORD OPERATING PUMP PRESSURE prig. <br /> i <br /> AND RECORD 9 n ML <br /> { IV PRESSURE STEP TEST IV PRESSURE STEP TEST-SUBMERSIBLE PUMP <br /> REMAINS ON THRU-OUT TEST PROCEDURE <br /> WITH BOTTOM SELECTOR IN PRESSURE STEP TEST WITH BOTTOM SELECTOR IN PRESSURE STEP TEST <br /> POSITION TURN ON PUMP POSITION ROTATE ISOLATOR FULLY(CO" <br /> RECORD TIME IN SECONDS GUAGE RECORD TIME IN SECONDS GUAGE <br /> NEEDLE REMAINS IN COLORED ZONE _L_SEC. NEEDLE ROAMS IN COLORED ZONE SEC: <br /> V 3 GALLON PER HOUR LEAK SIMULATED TEST V 3 GALLON PER HOUR LEAK SIMULATED TEST <br /> WITH BOTTOM SELECTOR IN 3 GPH TEST POSITION WITH BOTTOM SELECTOR IN 3 GPH TEST POSITION <br /> A) MEASURE AND RECORD VOLUME IN A) MEASURE AND RECORD VOLUME IN <br /> CALIBRATED BEAKER FOR 60 SECOND TEST 255 ML CALIBRATED BEAKER FOR 60 SECOND TEST ML <br /> B) OPEN DISPENSER NOZZLE OR PLACE BOTTOM B) PLACE BOTTOM SELECTOR IN DISPENSER <br /> SELECTOR IN DISPENSER NOZZLE POSITION. NOZZLE POSITION. <br /> FLOW RATE OF APPROX.1'h3GAL PER MINUTE FLOW RATE OF APPROX.1123GAL PER MINUTE <br /> WILL BE OBSERVED. WILL BE OBSERVED. <br /> DOES GUAGE NEEDLE MOVE TO LOWER DOES GUAGE NEEDLE MOVE TO LOWER <br /> END OF COLORED ZONE YES_K_NO ENO OF COLORED ZONE YES NO <br /> DOES FLOW RATE INCREASE TO APPROX. DOES FLOW RATE INCREASE TO APPROX. <br /> vh3GAL PER MINUTE YES X NO 11123GAL PER MINUTE YES NO <br /> C) CLOSE DISPENSER NOZZLE OR PLACE BOTTOM C) PLACE BOTTOM SELECTOR IN <br /> SELECTOR IN 3GPH TEST POSITION: 3GPH TEST POSITION: <br /> GUAGE RETURN TO COLORED GUAGE RETURN TO COLORED <br /> ZONE YES X NO ZONE YES NO <br /> GUAGE DOES NOT RETURN TO GUAGE DOES NOT RETURN TO <br /> COLORED ZONE YES NO X COLORED ZONE YES NO <br /> GAUGE GOES TO OPERATING GAUGE GOES TO OPERATING <br /> PRESSURE YES-NO x PRESSURE YES NO <br /> LEAK DETECTOR TEST FAIL LEAK DETECTOR TEST PASS <br /> • PLRPORAIVAPORLESS FORM 6E3A O <br /> 1 <br />