Laserfiche WebLink
M <br /> t <br /> E <br /> KLEINFELDER <br /> 5.2. ANALYTICAL METHODS AND REPORTED RANGES <br /> Each of the groundwater samples collected were submitted for analysis. The following is a list of <br /> the requested analyses and the reported ranges for groundwater samples obtained from the <br /> monitoring wells sampled; <br /> • Total Petroleum Hydrocarbons as gasoline [non-detect< 50 µg/1 to 160,000 µg/1] <br /> • Benzene [non-detect <0.50 µg/1 to 25,000 µg11.] <br /> • Toluene [non-detect < 0.50 µg/1 to 46,600 µg/1] <br /> • Ethylbenzene - - [non-detect < 0.50 µg11 to 3,300 gg/1] <br /> • Xylene [non-detect <0.50 µg/1 to 22,000 gg/1] <br /> • 1,2 DCA [non-detect <0.50 4g/1 to 3,100 µg/1] <br /> • EDB [non-detect<0.50 µg/1 to 1,200 µg/1] <br /> • TBA [non-detect <5.0 µg/l to 11 µg/1] <br /> • MTBE [non-detect<0.50 4g/1 to 0.64 gg/1] <br /> • DIPE [non-detect <0.50 µg/1]- <br /> • ETBE [non-detect <0.50 µg/1] <br /> TAME [non-detect<0.50 gg/1] <br /> For a summary of analytical data for the analytes listed above, please see Table 2 behind the <br /> "Tables"tab of this report. <br /> TPH-g was detected in 5 groundwater samples analyzed from MW-1, MW-2, NPI-70', 80', and <br /> 90' ranging from 340 µg/1 to 160,000 µg/1. Similarly, BTEX compounds were detected in the <br /> same groundwater samples collected ranging from 1.7 µg/1 to 46,000 µg11 (Toluene). TPH-g and <br /> BTEX compounds were not detected in 8 of the groundwater samples collected. <br /> 1,2-DCA was detected in 7 of the 13 groundwater samples. The detected concentrations ranged <br /> from 0.51 µg/1 (MW-DIS-12) to 3,100 µg/1 (NP1-801). The detected concentration of 0.51 µg/1 <br /> was .just above the laboratory reporting limit of 0.50 µg/1. The.detected concentrations of 1,2- <br /> DCA exceeded the Primary Maximum Contaminant Level (PMOL) for 1,2-DCA of 5 µg/l in five <br /> of the samples (MW-DIS-1, NPI-90', NPI-80', MW-DIS-11s, MW-DIS-15). 1,2-DCA was not <br /> detected in 6 of the 13 samples collected. <br /> EDB was detected in the groundwater samples collected from NPI-80', and NPI-90' with <br /> concentrations of 1,200 µg/l and 90 µg/l respectively. EDB was not detected in 11 of the 13 <br /> samples. <br /> MTBE was detected in MW-DIS-14s with a concentration of 0.64 µg/1. The Primary Maximum <br /> Contaminant Level (PMCL) for MTBE is 13 µg/l and the Secondary Maximum Contaminant <br /> Level (SMCL) for MTBE is 5 µg/1. The detected concentration of MTBE in MW-DIS-14s does <br /> not exceed the PMCL or the SMCL for MTBE this quarter. There were no detectable <br /> concentrations at or above the laboratory reporting limit for the oxygenates MTBE, DIPE, ETBE, <br /> and TAME in the groundwater sample collected from MW-DIS-15 this quarter. PMCLs are <br /> 12280.MON/ST03R1392 Page 10 of N <br /> ` ®2003,Kleinfelder,Inc October 13,2003 <br />