My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FILBERT
>
110
>
3500 - Local Oversight Program
>
PR0545039
>
ARCHIVED REPORTS_XR0011006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 2:06:50 PM
Creation date
12/10/2019 11:26:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011006
RECORD_ID
PR0545039
PE
3528
FACILITY_ID
FA0010186
FACILITY_NAME
DEL MONTE FOODS PLNT #33 - DISCO WH
STREET_NUMBER
110
Direction
N
STREET_NAME
FILBERT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15702009
CURRENT_STATUS
02
SITE_LOCATION
110 N FILBERT ST
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEMON 4 <br /> Quality Assurance Project Plan <br /> This quality assurance project plan describes the field and laboratory quality control procedures that will <br /> be implemented while completing tasks described in Section 3. <br /> 4.1 Quality Assurance Objectives <br /> The quality assurance objective for analytical data is to provide environmental data of known and <br /> acceptable quality. To meet this objective,the following field and laboratory quality control procedures <br /> will be implemented. <br /> 4.2 Calibration of Field Equipment <br /> The following field equipment will require calibration: <br /> • Photoionization Detector(PID) [e.g.,Hnu,or OVM] <br /> The PID meter will be calibrated to standards before and after each day's use in accordance with the <br /> procedures and schedules outlined in the particular model's handbook. The calibration standards for <br /> these instruments and their suppliers are listed below. <br /> Calibration Standards and Suppliers <br /> Instrument Calibration Standard Supplier <br /> Hnu Benzene,55 ppm HNu Systems,Inc. Newton <br /> Highlands,MA <br /> OVM Isobutylene,100 ppm HAZCO Services,Inc., Dayton, <br /> Ohio, <br /> The results of calibrations and records of repairs will be recorded in a field notebook. <br /> 1 <br /> Scheduled periodic calibration of testing equipment does not relieve field personnel of the responsibility <br /> of using properly functioning equipment. If an individual suspects an equipment malfunction,the device <br /> will be removed from service and tagged so that it is not inadvertently used,and the appropriate <br /> personnel will be notified so that recalibration can be performed or a substitute piece of equipment can be <br /> obtained. <br /> Equipment that fails calibration or becomes inoperable during use will be removed from service and <br /> either segregated to prevent inadvertent use,or tagged to indicate it is out of calibration. Such equipment <br /> will be repaired and satisfactorily recalibrated. Equipment that cannot be repaired will be replaced. <br /> Results of activities performed using equipment that has failed recalibration will be evaluated. If the <br /> activity results are adversely affected,the results of the evaluation will be documented and the <br /> appropriate personnel notified. <br /> Calibration instructions will be included with each instrument and accompany the instrument to the field. <br /> r <br /> CATEMPIW0RKPuAN_DC1-1.DoC 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.