MAP 07 '90 17:04 R.H.L. ?AMENTO 9166464679 P.14i14 <br /> Integrity Testing <br /> The Pipe Jacket is an open ended guttering system, therefore only a 5 psi air pressure soap test or hydrostatic-test <br /> need be performed to determine the systems containment integrity. <br /> Monitoring Capability <br /> The design of the Pipe Jacket Containment system is such that any leak in the primary pipe will flow from the high end of <br /> the secondary pipe to the low end which terminates into a collection sump. A leak can be monitored by periodic visual <br /> Inspections of the collection sump or by installing a leak detection probe which Is connected to an electronic monitor. <br /> Approximate leak location can be achieved by the Installation of zone observation wells installed at specific points along <br /> the piping line. These zone observation wells consist of a monitor fitting with a built in collection sump, to trap leaking <br /> product. This fitting is connected to a riser pipe which located under a street access manhole. The riser is sealed at the <br /> top by a cap that is air-tight but can be removed for pipe inspection. It can also be fitted with a leak detection probe. <br /> Total Containment, Inc. manufacturers the TCI Leak Detection System that is designed to be effectively installed <br /> in both the monitoring applications. <br /> Guide Specifications <br /> Short Form <br /> The contractor shall provide the Pipe Jacket Secondary Containment System, as manufactured by Total Containment, <br /> Inc., for containment of the underground primary piping system. This secondary containment system shall be installed <br /> and integrity tested in accordance with the manufacturers published installation instructions. <br /> Long Form <br /> Design: The secondary containment system for underground piping, shall be of such a design, that it wl, <br /> completely contain the primary piping from under the dispenser to the tank, Including the submersible pump housing <br /> and all swing Joints. It shall allow for complete inspection of all primary pipe connections, during the primary pipe <br /> air-pressure/soap testing, before the secondary containment system is sealed. <br /> Product Compatability: The secondary containment system for underground piping shall be compatible <br /> with the products to be stored. <br /> Corrosion Resistance: The secondary containment system for underground piping shall be non-corrosive, <br /> di-electric, non-degradable and resistant to attack from microbial growth. <br /> Structural Integrity: The secondary containment system for underground piping shall be of such a design and <br /> made of-materials to have sufficient strength to withstand the maximum underground burial loads. <br /> integrity Testing: The secondary containment system shall undergo a 5 psi air pressure/soap test or hydrostatic <br /> test upon completion to determine its secondary containment integrity. This testing shall be In compliance with the <br /> manufacturers published installation instructions. <br /> Monitoring Capability: The secondary containment system for underground piping shall have a monitored <br /> collection sump at the low end of the containment system. <br /> C011ectlon Sumps: The collection sumps located a the low end of the secondary containment system for <br /> underground piping shall meet the following requirements: <br /> 1. Provide water tight tank,connection, pipe exits and conduit exits. <br /> 2. Have a lid designed to prevent surface water from draining down into the sump. <br /> 3. Have a vent which will allow any collection of vapors to escape. <br /> 4. To have sufficient strength to keep out the surrounding back fill material. <br /> TOTAL . .. TM <br /> CONTAINMENT Pipe Jacket', <br /> Secondary Conlalnment syrt•m <br /> 15 East Uwchlan Avenue • Exton, Pennsylvania 19341 • 215-524-9274 <br />