soil sampling at desired intervals. Soil samples are collected analysis(VOA)vials,with"Teflon"septa,are used as sample
<br /> ' by either hammering(with a 140-pound drop hammer)or containers.
<br /> hydraulically pushing a conventional split-barrel sampler
<br /> i containing pre-cleaned 24neh-diameter brass tubes. A The groundwater sample is decanted into each VOA vial in
<br /> geologist or engineer from Apex Envirotech, Inc.,continuously such a manner that there is no meniscus at the top of the vial,
<br /> logs each borehole during drilling and constantly checks drill A cap is quickly secured to the top of the vial. The vial is then
<br /> cuttings toe indications of bath the first recognizable inverted and gently tapped to see if air bubbles are present. Jf.'
<br /> occurrence of groundwater and volatile hydrocarbons using none are present,the vial is labeled and refrigerated for
<br /> either a portable'photoionizabon detector,flame ionization delivery,under stria chain-of-custody,to the analytical
<br /> detector,or an explosimeter. The sampler is rinsed between laboratory. Label information should include a unique sample
<br /> samples and either steam cleaned or washed with all other identification number Job identification number,date,time,type
<br /> drilling equipment"between borings to minimize.the potential for of analysis requested,and the sampler's name.
<br /> cross-contamination.
<br /> For quality control purposes,a duplicate water sample is
<br /> Monitoring wells are cased with threaded,factory-perforated collected from each well. This sample may also be analyzed or
<br /> and blank Schedule 40 PVC. The perforated interval consists put on hold at the laboratory. When required,a trip blank,
<br /> of slotted casing;generally with 0.02Nnch wide by 1.5-inch prepared at the laboratory,is placed in the transport cooler. It
<br /> long slots,with 42 slots per foot. A PVC cap may be secured is labeled similar to the well samples,remains in the cooler
<br /> to the bottom of the casing with stainless steel screws;no during transport,and is analyzed by the laboratory along with
<br /> solvents or cements are used. Cantering devices may be the groundwater samples. In addition,a field blank may be
<br /> fastened to the casing to ensure even distribution of filter prepared in the field when sampling equipment is not
<br /> material and grout within the borehole annulus. The well dedicated. The field blank is prepared after a pump or bailer
<br /> casing is thoroughly washed and/or steam cleaned,or may be has.been either steam cleaned or properly washed,prior to use
<br /> purchased as,pre-�_,leaned,prior to installation, in the next well,and is analyzed along with the other samples,
<br /> The field blank analysis demonstrates the effectiveness of the
<br /> After setting the casing inside-the hollow-stem auger,sand or "in-field cleaning procedures to prevent cross-contamination.
<br /> gravel filter material is poured into the annular space to fill from
<br /> boring bottom to generally 1 foot above the perforated interval. To minimize the potential for crass-contamination between
<br /> A 1-to 2400t thick bentonite plug is set above this filter material wells,all well developinent and water sampling equipment not
<br /> to prevent grout from infiltrating the filter pack Either neat dedicated to a well is either steam cleaned or properly washed .
<br /> cement,containing about 5 percent bentonite,or sand-cement between use. As a secondary precautionary measure,wells
<br /> grout is then tremmied into the annular space from the top of are sampled in order of least to highest concentrations as
<br /> the bentonite plug to near surface. A traffic-rated vault is established by available previous analytical data.
<br /> installed around each wellhead for wells located in parking lots
<br /> or driveways,while steel"stovepipes"are usually set over in the event the water samples cannot be submitted to the
<br /> wellheads in landscaped areas. analytical laboratory on the same day they are collected(e.g.,
<br /> due to weekends or holidays),the samples are temporarily
<br /> After installation,-the wells are thoroughly developed to remove stored until the first opportunity for submittal either on water ice
<br /> residual drilling rrikenals from the wellbore,and to improve well in a cooler,such as when in the field,or in refrigerator at
<br /> performance by removing fine material from the filter pack that Apexs office. .
<br /> may pass into the well. Well development techniques used
<br /> may include pumping,surging,bailing,swabbing,jetting, SOP " 1 2
<br /> flushing,and air-lifting, All development water is collected MEASURING LIQUID LEVELS USING
<br /> either in drums or-tanks for temporary storage,and properly WATER LEVEL METER OR INTERFACE
<br /> disposed of depehding on laboratory analytical results. To PROBE
<br /> minimize the poterrtial for cross-contamination between wells,
<br /> all development equipment is either steam cleaned or properly Field equipment used for liquid-level gauging typically includes
<br /> washed prior to use. Following development,the well is the measuring instrument(water-level meter or interface probe)
<br /> allowed to stand undisturbed for a minimum of 24 hours before and product bailer(s). The field kit also includes cleaning
<br /> its first sampling.' supplies(buckets,solution,spray bottles,and deionized water)
<br /> i
<br /> to be used in cleaning the equipment between wells.
<br /> SOP - 7
<br /> GROUNDWATER PURGING AND Prior to measurement,the instrument tip is lowered into the well
<br /> SAMPLING until it touches bottom. Using the previously established top-of-
<br /> casing or top-of-box(i.e.,wellhead vault)point,the probe cord
<br /> Prior to water sampling,each well is purged by evacuating a (or halyard)is marked and a measuring tape(graduated in
<br /> „ minimum of three�watted well-casing volumes of groundwater. hundredths of a foot)is used to determine the distance
<br /> When required,purging will continue until either the discharge between the probe and and the marking on the cord. This
<br /> water temperature;conductivity,or pH stabilize,a ma>amum of measurement is then recorded on the liquid-tevei data sheet as
<br /> ten wetted-casing volumes of groundwater have been the"Measured Total Depth"of the well,
<br /> recovered,or the'wall is bailed dry. When practical,the
<br /> 4.
<br /> groundwater sample should be collected when the water level When necessary in using the interface probe to measure liquid
<br /> in the well recovers to at least 80 percent of its static level. levels,the probe is first electrically grounded to either the metal
<br /> stove pipe or another metal object nearby. When no ground is
<br /> The sampling equipment consists of either a"Teflon"bailer, available,reproducible measurements can be obtained by
<br /> PVC bailer,or stainless steel bladder pump with a"Teflon" clipping the ground lead to the handle of the interface probe
<br /> bladder. If the sampling system is dedicated to the wall,then case.
<br /> the bailer is usually"Teflon,"but the bladder pump is PVC with
<br /> a polypropylene bladder. In general and depending on the
<br /> intended laboratory analysis,40-millil'ter glass,volatile organic
<br /> i
<br /> SOP- Monitoring Wells
<br /> ails
<br />
|