A mobil substation (T-4-2913) trailer and a tractor are parked next to <br />the Mobil Substation (IT.5.0-6), until needed for emergencies. This mobil <br />substation consists of a transformer with 1,710 gallons of transformer <br />oil. <br />These mobil substations are designed for outdoor use and to withstand <br />transportation, it is unlikely that leaks would develop while in storage. <br />The remote potential of a casing rupture could result in spill volumes <br />between 0-4195 gallons. The size of such a rupture on a transformer in <br />storage should be small. Since these transformers are located in a <br />visible area of the yard, any spill would be noticed promptly and <br />maintenance personnel could immediately attend to these spills. In event <br />of a major spill, Emergency Plan Section 4 will be implemented. <br />vi. Operating Transformers <br />The transformer bank has three aboveground transformers and regulators <br />for 60KV to 12KV local distribution substation. These transformers are <br />mounted on concrete pads and protected in a rock: blotter. The regulators <br />are also mounted on concrete pads. The entire area is surrounded by an <br />8 -inch wood berm, filled with 7 -inches of earthen materials. The total <br />volume of transformer oil in these equipment is 13,473 gallons. <br />There is a step-down transformer located in the southwest corner of the <br />yard. It is used to furnish electrical power to this Service Center. <br />This transformer contains 265 gallons of transformer oil. <br />These transformers are manufactured for outdoor use and must retain oil <br />to operate properly. It is unlikely that leaks would develop. The <br />highest potential for spillage is during a casing rupture. <br />vii. Transformer Storage Areas <br />There are four areas used to store large quantities of oil filled <br />transformers. Three areas, used to maintain an inventory of oil filled <br />transformers which may be required at job sites, are as follows: <br />1. Transformer Storage Area 1: <br />This storage area is located in the northwest corner of the yard. <br />Approximately 600 transformers containing from 3 to 50 gallons of <br />transformer oil each are stored around the helicopter pad. <br />2. Transformer Storage Area 2: <br />This area is located in the southeast corner of the yard. <br />Approximately 150 transformers containing 100 to 1,517 gallons of. <br />transformer oil each are stored on concrete parking island dividers. <br />This area is bermed on the north, south and west sides and slopes <br />down to a catch basin on the west side. <br />REV. 11-87 <br />3-6 <br />