Laserfiche WebLink
1 <br /> • Historical Background: River City Petroleum and Connell Motor Lift Truck <br /> ' Page 7 of 13 <br /> samples from CPT P32 as follows: <br /> ' 0 TPH-ss and TPH- were detected at concentrations as high as 2 300 milligram per kilogram <br /> g g gr' p gi' <br /> (mg/kg) in soil sample P32-60, TPH-d was detected in the same sample at a concentration <br /> ' of 1,300 mg/kg. <br /> • TPH-g and TPH-ss were both detected in soil sample P32-70 at a concentration of 1,800 <br /> ' mg/kg,TPH-d was detected, in the same sample, at a concentration of 2,000 mg/kg. TPH-g <br /> and TPH-ss were detected in soil sample P32-78 at concentrations of 41 and 72 mg/kg, <br /> respectively. TPH-d was not detected in the same sample. <br /> iToluene,ethylbenzene and xylene were detected,in the above samples,at concentrations as <br /> high as 2.6 mg/kg.The volatile organic compound methanol was detected in one soil sample, <br /> ' P32-60, at a concentration of 310,000 micrograms per kilogram(gg/kg). <br /> • Oxygenated fuel additives were not detected in the soil samples analyzed. <br /> A total of five "grab" ground water samples were collected from CPT P30 through P33 and <br /> submitted for laboratory analysis for the above mentioned constituents. <br /> ' TPH-g and TPH-ss were detected in the grab water sample collected from boring P32 at 60 <br /> feet bsg, at concentrations of 120,000 micrograms per liter(µg/1). TPH-g and TPH-ss were <br /> 1 detected in water samples collected from boring P32 at 100 feet bsg,at concentrations of 440 <br /> and 140 µg/1, respectively. <br /> ' • TPH-d was detected in water samples collected from boring P32 at 60 and 100 feet bsg, at <br /> concentrations of 230 and 330 gg/l, respectively. <br /> • TPH-g and TPH-ss were detected in water samples collected from boring P33 at 80 feet bsg, <br /> ' at concentrations of 680 and 210 µg/1, respectively. TPH-d was detected in the same water <br /> sample collected from boring P33 at a concentration of 230 µg/1. <br /> • BTEX compounds were detected in the ground water samples at concentrations as high as <br /> 760 gg/l (P32-60, xylene). Benzene was detected in the ground water sample from P32-60 <br /> at a concentration of 96 µg/1 . <br /> • 1,2-DCE was detected at a concentration of 1.4 gg/1 in the water sample collected from P30 <br /> at a depth of 100 feet bsg and 1,2-DCA was detected at a concentration of 25 µg/1 in the grab <br /> ' ground water sample collected from P33 at approximately 80 feet bsg. <br /> • No other petroleum hydrocarbon constituents or fuel oxygenated compounds were detected <br /> ' by the laboratory analyses. <br /> Advanced GcoEnvironmental,Inc. <br />