Laserfiche WebLink
14 <br /> N d Supp) C—ii, D..W, -bnleps No pno Slrsallsl /Cny Slpls Dere of T- <br /> 15. TANK TO TEST 16. CAPACITY From <br /> S f- By most accurate El Station Chart <br /> Nominal Capacity Q O c <br /> by Pwnwn capacity chart available /b �OrY ❑Tank Manufacturer's Chart <br /> bentny � G41w. /Gnllona <br /> ff — <br /> Company Engineering Data <br /> �iESA�L Is there doubt as to True Capacity? N O ❑Chute supplied with Petro Tilea—..GIaM See SM:lion'DETERMINING TANK CAPACITY' <br /> ❑Other <br /> 17. FILL-UP FOR TEST SIwp R.,a,n,. Ta.I G.tbn <br /> b 19 m Gallon. <br /> 5M cotter 8a <br /> b.1—Fl Inventory / <br /> w Ile In. Gallons ii <br /> Ful up STICK BEFORE AND AFTER EACH COMPARTMENT DROP OR EACH METERED DELIVERY QUANTITY !g <br /> TO.Dnuroar 9'Y Proeua,n NO I&M(up b hu pwel S 7— F L <br /> 18. SPECIAL CONDITIONS AND PROCEDURES TO TEST THIS TANK Observed Gravity S-2_7 VAPOR RECOVERY SYSTEM <br /> NONE" <br /> See manual sections applicable.Check below and record procedure In log(2e). Observed Temperatures 6-3 ❑Stage 1 <br /> %.Svff f C <br /> Water In tank High water table In tank excavation. Lines)being tested with LVLLT G��A,a�{aa•�-p4.GevMy .577.6 ❑Stage II <br /> ❑Yea L7,,/No Yes❑ <br /> [�'o ❑Yee u No G O.E. <br /> 19. TANK MEASUREMENTS FOR 21. TEMPERATURE/VOLUME FACTOR(a)TO TEST THIS TANK <br /> TSTT ASSEMBLY isToday warmer El Cooler?El Product in Tank—°F Fill-up Product on truck—°F Expected Change(+or-) <br /> Bottom of tank Grade'..................................... <br /> Add 30•for 4'L........... _s' 22. Thermal-Sendor reading after circulation 6 SS T/s'6 °F <br /> a <br /> Add 24'for 3"or air seal....._..,..._.._._. <br /> Total tubing to assemble Approximate.. ..... ......... !, Il - 23. Digits per°F m range of expected change J 7 <br /> o,plu <br /> 20. EXTENSION HOSE SETTING _ 24. gallons <br /> Tank top to grade'............. .......................... total quantity in �coenrcient of expansion for volume change In this tank <br /> Extend hose on auction tube e'or more lull lank(16. 17) involved product per'F <br /> below tank top.. ........................ ..... ...... 25. /1. S -/G 2 7 1r'/ 75- <br /> Tms Is <br /> volume change per°F(24) Digits per°F in test Volume change per digit teal <br /> 'If Fel pipe extends above grade,use top of fill. Range(23) Compute to 4 decimal places. lector(e) <br /> ARRIVED AT TEST SITE AND MEASURED FOR WATER ON TANK BOTTOM <br /> \ TRANSPORT TRUCK TOPPED OFF TANK,AND TOOK INVENTORY OF PRODUCT <br /> REMOVED FILL CAP AND SPLASH TUBE.SET-UP TEST EQUIPMENT <br /> 26. 30. HYDROSTATIC 31. VOLUME MEASUREMENTS IV) 34TEMPERATURE COMPENSATION 36.NET VOLUME 3YIEUMUTATED <br /> LOG Of TEST PROCEDURES PRESSURE RECORD TO.001 GAL USE FACTOR UI CHANGES CHANGE <br /> CONTROLFACH READING <br /> 27. 28. 29. sMndPp.L.wl 32. PI.d.m Produce 35. 36 37. .mP.•.u,. AI L....,...< <br /> DATE R." YVKn. Graduau NO....ll Cnana LpnpuMlwt Aaluummr &K Lm Munro <br /> Record details of setting up ND LZ u InnmK Mew. Ice I.I <br /> Sanrp LDw- E.D.n.on. pdune M— Y LDS I—- <br /> TIME and running test.(Use lull d eNmA Seo.. Alla PrPducr pRD�y Ic1 C.nirW,pn- f.Dappanl•la Cn."...e pan <br /> 124 eq length of line it needed R..svp Rn1a.0 RnGnil RMalne R.cownd l <br /> nYRvr .vin <br /> Fill Test Equipment with Product&Pump Primed and Running Factor A= . Ol4w_r <br /> FIRST SENSOR READING Z c, <br /> START SENSOR READING f /.2 — - el t q fi, <br /> 'f CONTINUE HIGH LEVEL TEST 2 - o G 7a ­a5o 0,Z it 1_1 9 197q <br /> r <br /> :Y y/. Z <br /> ';ii Y/.7 E' 560 5+ �i --0-00 <br /> s 2.0 ./90 '10006 6 — / <br /> Ti- <br /> Test concluded 'Tt found to be < hl or not tight <br /> on this day at a /2 level readino of gallons per our l_-�_ <br />