Laserfiche WebLink
Grorencltivater alorritorit:g Work Plan <br /> 1950 West Fremont Sheet,Stockton, California <br /> Samples to be analyzed for dissolved metals will be field filtered prior to analysis. <br /> 2.4 QUALITY ASSURANCE/QUALITY CONTROL <br /> 2.4.1 Field Quality Control Samples <br /> To veriA, the appropriateness of the quality assurance and quality control(QA/QC)procedures during the <br /> field program,the QA/QC plan includes the collection and analysis of: <br /> • One field duplicate groundwater sample,and <br /> • One trip blank to accompany each cooler containing the samples for VOC analysis. <br /> All samples will be delivered under chain of custody for analysis by a state-certified analytical laboratory. <br /> Field Duplicates: Field duplicate groundwater samples are additional samples that will be collected <br /> independently at one sampling location during one act of sampling. Both samples will be analyzed for <br /> the same parameters to verify sampling and analytical precision. Field duplicates for the groundwater <br /> samples will be collected by sequentially filling a sample container for the parent sample and then the <br /> identical sample container for the field duplicate sample, starting with the containers for volatile analyses, <br /> followed by the containers for other analyses. Each duplicate will be assigned separate sample numbers <br /> for blind submission to the laboratory. <br /> Trip Blank Samples: Trip blank samples are samples that will be collected to check for potential cross- <br /> contamination during sample collection. shipping, or laboratory handling. <br /> 2.4.2 Laboratory Quality Control Samples <br /> Laboratory QC samples will be analyzed to monitor the precision and accuracy of the laboratory results. <br /> The laboratory QC samples will consist of method blanks and laboratory control samples. In addition. <br /> surrogate spikes and internal standards will be added to samples and evaluated.as applicable for each <br /> method. <br /> 2.4.3 Data Review and Validation <br /> The analytical data will be reported as USEPA Level It data that will consist of the following: <br /> • A copy of the signed COC and sample receiving records indicating the date and time of sample <br /> receipt in laboratory. <br /> • Adequate information to cross-reference field sample numbers to laboratory sample numbers and <br /> to identify applicable laboratory QC samples with the field samples. <br /> • Summary forms which include the analytical method used,date of extraction(if applicable), date <br /> Project 102790 7 December 2007 <br />