Project No.013-10141 <br /> Page No. 8 <br /> hold at the laboratory. Krazan recommends that the deeper samples be analyzed to further evaluate the <br /> vertical extent of contamination. <br /> Analytical results of soil samples collected from the areas of the inactive wash drain located within the <br /> southern portion of the site building and the active clarifier, wash rack, and drain located within the <br /> northern portion of the site building did not reveal subsurface impacts that would require further <br /> investigation. Additionally, concentrations of heavy metals detected in the soil samples, collected <br /> adjacent to the clarifiers, drains, and wash rack, were below their respective ESLs and RSLs, and are <br /> therefore, not considered to pose a significant threat to human health and/or the environment within the <br /> areas where samples were collected and analyzed. <br /> Based on Krazan's field observations and review of the analytical results, further assessment of the <br /> inactive clarifier,located within the southern portion of the subject site, is recommended at this time. <br /> 9.0 RELIANCE <br /> This report was prepared solely for use by Client and should not be provided to any other person or entity <br /> without Krazan &Associates' prior written consent. No party other than Client may rely on this report <br /> without Krazan&Associates' express prior written consent. Reliance rights for third parties will only be <br /> in effect once requested by Client and authorized by Krazan & Associates with authorization granted by <br /> way of a Reliance Letter. The Reliance Letter will require that the relying party(ies)agree to be bound to <br /> the terms and conditions of the agreement between Client and Krazan &Associates as if originally issued <br /> to the relying party(ies),or as so stipulated in the Reliance Letter. <br /> 10.0 LIMITATIONS <br /> This assessment of the subject site has been limited in scope. Although the work was conducted in <br /> accordance with industry standards and employing a professional standard of care, no warranty is given, <br /> either expressed or implied, that buried structures, which would not have been disclosed through this <br /> assessment,do not exist at the subject site. Therefore,the data obtained are clear and accurate only to the <br /> degree implied by the sources and methods used. <br /> This report is provided for the exclusive use of and reliance upon by Client and shall be subject to the <br /> terms and conditions in the applicable contract between Client and Krazan. Any third party use of this <br /> KRAZAN&ASSOCIATES,INC. <br /> Conducting AssessmentsNatiom ide <br /> 1310141 United Remak LSI DRAFr.doc <br />