Laserfiche WebLink
i <br /> Ouality Assurance Procedures <br /> To prevent contamination of the samples, Clearwater personnel adhere to the following procedures in the field <br /> i <br /> • A new,clean pair of latex gloves is put on prior to sampling each well <br /> • Wells-are gauged, puiged and groundwater samples are collected in the expected order of increasing degree of <br /> contamination based on historical analytical results <br /> • All purging equipment is thoroughly decontaminated between each well, using the procedures previously <br /> described at the beginning of this section <br /> • During sample collection for volatile organic analysis, the amount of air passing through the sample is <br /> minimized This helps prevent the air from stripping the volatiles from the water Sample bottles are filled by <br /> slowly running the sample down the side of the bottle until there is a convex meniscus over the mouth of the <br /> bottle The lid is carefully screwed onto the bottle such that no air bubbles are present within the bottle If a <br /> bubble is present, the cap is removed and additional water is added to the sample container After resealing the <br /> sample container, if bubbles still are present inside, the sample container is discarded and the procedure is. <br /> repeated with a new container <br /> Laboratory and field handling procedures may be�monitored, if required by the client or,regulators, by including <br /> quality control(QC) samples for analysis with the groundwater samples Examples of different types of QC samples <br /> are as follows <br /> 1 5 1 I*' <br /> • Trip blanks are prepared at the analytical laboratory by laboratory personnel to check field handling procedures <br /> Trip blanks are transported to the project site in the same manner as the laboratory-supplied sample containers <br /> to be filled They are not opened, and are returned to the laboratory with the samples collected Trip blanks are <br /> analyzed for purgeable organic compounds <br /> • Equipment blanks are prepared in the'field to determine if decontamrnnation of field sampling equipment has <br /> • <br /> been effective The sampling equipment used to collect the groundwater samples is rinsed with distilled water <br /> - whichx is then decanted into_laboratoryrsupplied_containers __The_equmpment_blanks are transported to the - - --- <br /> _ laboratory, and are analyzed for the same chemical constituents as the samples collected at the site -- -yh�- - - -- — <br /> • Duplicates are collected at the same time standard groundwater samples arc collected,They are analyzed for the <br /> same compounds in order to verify the reproducibility of laboratory data They are usually collected from only <br /> one well per sampling event The duplicate is assigned an identification number that will not associate it with <br /> the source well <br /> 1 <br /> Generally,, trip blanks and field blanks verify field handling and transportation procedures Duplicates verify <br /> laboratory procedures The configuration of QC samples is determined by Clearwater depending on site conditions <br /> and regulatory requirements <br /> • <br /> CLEARWATER GROUP(G WS) 2 revised September 9,2005 <br />