Laserfiche WebLink
v � <br /> . A S S 0 C I A T E S f N C <br /> was sampled and transferred to appropriate sample containers, using a clean, disposable bailer <br /> with a bottom-emptying device to reduce volatilization Sample containers were then labeled <br /> with sample identification, placed on ice, and shipped under chain-of-custody to Sequoia <br /> Analytical Feld development/purge logs are presented in Attachment 1 <br /> Laboratory Analysis <br /> The groundwater sample from well MW I was analyzed by Sequoia Analytical for total <br /> petroleum hydrocarbons as gasoline (TPHg), benzene, toluene, ethylbenzene, and xylenes <br /> (BTEX) by EPA Methods 801518020,and oxygenate fuel additives by EPA method 8260 <br /> Laboratory Results <br /> Only methyl tert-butyl ether (MTBE) was detected above the laboratory method detection limits <br /> The reported MTBE concentration was 3 98 parts per billion (ppb) No other constituents were <br /> detected <br /> Analytical results are summarized in Table 2 Laboratory data sheets and chain-of-custody <br /> documentation are provided in Attachment 2 <br /> • WELL SURVEY <br /> ATC reviewed PHS/EHD groundwater well construction logs, Department of Water Resources <br /> (DWR) groundwater well construction Iogs, and conducted a site walk in the vicinity of the site <br /> to identify any groundwater wells located within 2,000-foot radius of the site The search <br /> revealed thirteen potential wells located within approximately 2,000 feet of the site None of <br /> these wells are located within 800 feet of the site The approximate well locations are shown on <br /> Figure 3 - <br /> The wells were located on the map according to "well location" description information provided <br /> on the well construction logs Available well construction details are included in Table 3 <br /> In order to assess hydraulic characteristics beneath the site ATC reviewed data collected from a <br /> nearby subsurface investigation Marley Cooling Tower Company (MCTC), located east and <br /> adjacent to Franklin High School, is currently conducting corrective action measures to address <br /> soil and groundwater impacted with chromium In brief, MCTC has installed numerous <br /> monitoring and extraction wells to investigate subsurface conditions beneath the site and <br /> determine the appropriate method for dissolved chromium remediation Their extensive <br /> chromium subsurface investigations performed to date have determined that there are four <br /> hydrostatigraghic units underlying the site These four hydrostati graphic subunits are 1) the <br />. shallow zone, 2) the 100 foot sand zone, 3) the intermediate zone, and 4) the deep zone The <br /> shallow zone extends from the water table to approximately 80 feet bgs The 100-foot sand <br /> occurs between approximately 80 and 120 feet bgs The intermediate zone occurs between <br /> w 117292 00011reportsl3 qmr 2000 doc 2 <br />