Laserfiche WebLink
TABLE 1 <br /> GEOTECHNICAL AND ENVII2ONMENTAL TESTING <br /> Depth(feet, <br /> Boring Location Purpose bgs) Laboratory Testing' Sampling <br /> CB-1 North Pond Bottom Vadose Zone Charaterization 100 Chloride(Total and D-WET),MC/DD Every 5 ft,starting at the ground surface <br /> CB-2 North Pond Bottom Vadose Zone Charaterization 50 Chloride(Total and D-WET),MC/DD Every 5 ft,starting at the ground surface <br /> CB-3 North Pond Bottom Vadose Zone Charate=tion 50 Chloride(Total and D-WET),MC/DD Every 5 ft,starting at the ground surface <br /> Chloride(Total and D-WET),MC/DD,Max. <br /> Berm Between North Density,Consolidation,Unconfined,Matric _ <br /> CB-4 and South Ponds Geotechnical 100 Suction Every 5 ft,starting at the ground surface <br /> CB-5 South Pond Bottom Vadose Zone Charaterization 50 Chloride(Total and D-WET),MC/DD Every 5 ft,starting at the ground surface <br /> None-tip resistance,friction sleeve <br /> CPT-1 North Berm Geotechnical 50 resitance,friction ratio,and soil classification <br /> Berm Between North None-tip resistance,friction sleeve <br /> CPT-2 and South Ponds Geotechnical 60 resitance,friction ratio,and soil classification <br /> None-tip resistance,friction sleeve <br /> CPT-3 South Berm Geotechnical 50 resitance,friction ratio,and soil classification <br /> Note:'-Proposed Geotechnical Laboratory Testing,assume: <br /> Moisture Content 70 tests <br /> MC/DD 30 tests <br /> Max.Density 4 tests <br /> Consolidation 4 tests <br /> Unconfined 4 tests UU or Quick test <br /> Atterberg 8 tests <br /> Grain size 20 tests <br /> Matric Suction 6 tests <br /> R-Value 2tests <br /> N.TroposaIT04-7204(Sbt4 Brmas-field exploratim)Vtables 10-12-04.xls GOLDER ASSOCIATES <br />