My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_FILE 1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
455
>
3500 - Local Oversight Program
>
PR0545202
>
SITE INFORMATION AND CORRESPONDENCE_FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2020 9:47:17 AM
Creation date
1/27/2020 9:20:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 1
RECORD_ID
PR0545202
PE
3528
FACILITY_ID
FA0003124
FACILITY_NAME
7-ELEVEN INC. STORE #20304
STREET_NUMBER
455
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
455 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> Ir _ <br /> \ L 7 <br /> Walt Lubcke <br /> Page 2 , <br /> 4. In March, 1989,three (3) underground storage tanks.were removed without inspection and <br /> monitoring well seven (7) destroyed without a well^destruction permit. According to the <br /> approved tank removal plan, submitted by Petro-Check, Incorporated, American <br /> Environmental Management Corporation was contracted to perform laboratory analysis on <br /> samples taken, under chain of custody, at the time of the tank removal. Please submit a <br /> map indicating where the samples were taken, the chain of custodies accompanying <br /> samples, and the results of analysis. <br /> 5. Additionally, at some time, the tank pit was backfilled. Please provide information as to <br /> when it was backfilled and the type of backfill used. ' <br /> 6. Plate one (1) of the PAR was a map dated January 1988. This map indicated the presence <br /> of MWA. Upon a site inspection conducted April 9, 1991,.this well was not located. MWA <br /> is not being regularly sampled. Please provide further information regarding this well. <br /> 7. Sampling procedures, outlined in the LUFT Manual,xequiring that samples be stored and <br /> transported at 40C in an ice chest, must be adhered to. In the Field Procedures section of <br /> the May, 1989 Sampling-Monitoring Well Report, it was stated that samples were stored in <br /> a cooled ice chest. Please be informed that field procedures must be altered to reflect LUFT <br /> sampling procedures. Furthermore, be informed that'48 hours notice must be given to this <br /> office prior to any site activity, this includes sampling. <br /> Monitoring should be initiated pursuant to Section 2652(d) of the Underground Storage Tank Regulations <br /> (California Administrative Code, Title 23, Subchapter 16). The monitoring report shall be submitted to <br /> PHS/EHD and Central Valley Regional Water Quality Control Board (CVRWQCB) until the investigation and <br /> cleanup of the site is deemed adequate. The report is to show the: . <br /> -status of investigation and cleanup activities including the results`of all investigation completed to <br /> date; j <br /> -proposed continuing or next phase of investigation; <br /> -method of cleanup proposed or implemented,.schedules for the completion of the investigation of <br /> the site and remediation; <br /> -monitoring well data including groundwater elevation, pH, conductivity, gradient; <br /> -analytical results of groundwater or soil sampling; and <br /> -a site map showing the "zero Iine" of contamination, if known, and changes in the above <br /> measurements over the last quarter. <br /> Pursuant to Section 280.67, Subpart F of 40CFR of the Federal Register, PHS/EHD, will conduct a public <br /> notice to consider comments.on your Final Remedial Plan/Corrective Action Plan. <br /> .j <br />
The URL can be used to link to this page
Your browser does not support the video tag.