SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
9504
>
2900 - Site Mitigation Program
>
PR0508462
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 12:22:14 PM
Creation date
1/30/2020 11:02:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508462
PE
2960
FACILITY_ID
FA0008093
FACILITY_NAME
CONTINENTAL GRAIN CO
STREET_NUMBER
9504
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
9504 S HARLAN RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Californi#egional Water Quality CoVol Board , <br /> ` \- Central Valley Region <br /> Karl E. Longley,ScD,P.E.,Chair •�:%' <br /> Linda S.Adams Arnold <br /> Secretaryfor Sacramento Main Office Schwarzenegger <br /> Environmental 11020 Sun Center Drive#200,Rancho Cordova,California 95670-6114 Governor <br /> Protection Phone(916)464-3291 •FAX(916)464-4645 <br /> hup://www.waterboads.ca.gov/centralvalley <br /> 5 December 2007 W LS —C-9"EO V LSD <br /> Mr. James Taylor DEC 0 7 2007 <br /> ContiGroup Companies EWIR%WNTHEAETM <br /> AON Center PERMIT/SERVICES <br /> 200 E. Randolph, Suite 1900 <br /> Chicago IL 60601 <br /> TRANSMITTAL OF MONITORING AND REPORTING PROGRAM NO. R5-2007-0826 <br /> FRENCH CAMP GRAIN ELEVATOR, 9504 S. HARLAN ROAD, SAN JOAQUIN COUNTY <br /> ContiGroup is conducting investigation and remediation of carbon tetrachloride and other <br /> volatile pollutants at its former facility at 9504 South Harlan Road. In 2005, ContiGroup <br /> injected zero-valent iron into the subsurface which is reducing concentrations of pollutants <br /> near the injection points, and in letters dated 4 October 2007 and 5 December 2007, Central <br /> Valley Regional Water Quality Control Board (Regional Water Board) conditionally concurred <br /> with a pilot study which will recirculate groundwater through the zero valent iron injection <br /> points. The objective is to accelerate the rate of groundwater cleanup by exposing more <br /> groundwater to the iron. In the 4 October 2007 letter, Regional Water Board staff transmitted <br /> a draft Monitoring and Reporting Program (MRP) that reduces the frequency of groundwater <br /> plume monitoring from quarterly to semi-annually and includes a section particular to the pilot <br /> groundwater recirculation system. <br /> We received your comments on the draft MRP in an email dated 29 October 2007. Regional <br /> Water Board staff concur with your comments and the attached Monitoring and Reporting <br /> Program No. R5-2007-0826 incorporates your suggestions. The changes in the attached <br /> MRP are as follows: <br /> • Both extraction/injection well pairs may be operated, but may not be operated concurrently. <br /> • Monitoring well MW-3C is added to the program. <br /> • In the event of the recirculation system shut-down, Regional Water Board staff shall be <br /> notified within seven days instead of within 48 hours. <br /> • Language referring to annual reports has been changed to reflect semi-annual reporting <br /> periods. <br /> • Directives to improve remediation system effectiveness are modified by the phrase "if <br /> warranted". <br /> In a 20 November 2007 email, your consultant, Ms. Linda Huff of Huff and Huff Inc. notified <br /> Ms. Amy Terrell of my staff that ContiGroup concurs with the changes to the draft MRP. <br /> California Environmental Protection Agency <br /> Qa Recycled Paper - <br />
The URL can be used to link to this page
Your browser does not support the video tag.