Laserfiche WebLink
MONITORING AND REPORTING PROGRAM NO.5-01-825 • -2 - <br /> KOPPEL STOCKTON TERMINALS,INC.,MUNCO,INC., <br /> CHEVRON CHEMICAL COM PANY AND CARGILL,INC. <br /> KOPPEL STOCKTON TERMINAL,SAN JOAQUIN COUNTY <br /> REPORTING <br /> When reporting data, the Discharger shall arrange the information in tabular form so that <br /> the date, the constituents, and the concentrations are readily discernible. The data shall <br /> be summarized in such a manner as to illustrate clearly the compliance with this Order. <br /> As required by the California Business and Professions Code Sections 6735, 7835, and <br /> 7835.1, all reports shall be prepared by a registered professional or their subordinate and <br /> signed by the registered professional. <br /> Semi-annual reports shall be submitted to the Board by the 1st day of the second month <br /> following the end of each calendar quarter (i.e., by 1 May and 1 November) until <br /> such time as the Executive Officer determines that the reports are no longer necessary. <br /> Each semi-annual report is to include the following minimum information: <br /> (a) a description of the semi-annual groundwater sampling event, including field logs. At <br /> a minimum, field logs shall contain water quality parameters measured before, <br /> during, and after purging, method of purging, depth of water, volume of water <br /> purged, etc.; <br /> (b) groundwater contour maps for all groundwater zones, if applicable; <br /> (c) isocontour contaminant concentration maps for all groundwater zones, if applicable; <br /> (d) a table showing well construction details such as well number, groundwater zone <br /> being monitored, coordinates (northings and eastings), ground surface elevation, <br /> reference elevation, elevation of screen, elevation of bentonite, elevation of filter <br /> pack, and elevation of well bottom; <br /> (e) a table showing historical lateral and vertical (if applicable) flow directions and <br /> gradients; <br /> (f) cumulative data tables containing the water quality analytical results and depth to <br /> groundwater; <br /> (g) a copy of the laboratory analytical data report; <br /> (h) if applicable, the status of any ongoing remediation, including cumulative information <br /> on the mass of contaminant removed from the subsurface, system operating time, the <br /> effectiveness of the remediation system, and any field notes pertaining to the <br /> operation and maintenance of the system; and <br /> (i) if applicable, the reasons for and duration of all interruptions in the operation of any <br /> remediation system, and actions planned or taken to correct and prevent interruptions. <br />