4.0 PROPOSED APPROACH TO ADDITIONAL SITE ASSESSMENT <br /> Sampling procedures will generally conform to the requirements of the CVRWQCB, the <br /> Department of Toxic Substances Control (DTSC), the United States Environmental Protection <br /> Agency (EPA), and the State Water Resources Control Board UST cleanup fund guidelines (Tank <br /> Fund). Laboratory results will be evaluated using the SFRWQCB ESLs, EPA Regional Screening <br /> Levels (RSLs) and/or the August 2012 State Water Resources Control Board (SWRCB) Low-Threat <br /> UST Case Closure Policy. <br /> Borings MW-1, MW-2 and MW-3, will be advanced with a HSA drill rig and borings B12, B13, and <br /> B14 will be advanced with a direct-push drill rig operated by a State-licensed (C57) water well <br /> drilling contractor. Soil samples will be collected from the following depths: <br /> • Soil samples will be collected from borings MW-1, MW-2 and MW-3 at depths of 5, 10, <br /> 15, 20, 25, 30, and 35 feet bgs, and from borings B12, B13 and B14 at depths of 5, 10 and <br /> 15 feet bgs. <br /> Soil sampling activities are detailed in Section 5.3. <br /> Additional Site Assessment Work Plan <br /> Heliostockton Property <br /> 434 Dr.Martin Luther King Jr.Boulevard <br /> Stockton,California <br /> Partner Project Number SM17-191672 <br /> RWQCB Case#:392004 <br /> January 9,2018 <br /> Page 8 <br />