My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:35:59 PM
Creation date
2/6/2020 8:58:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
574
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s*gov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility 99Shell Facility 7700 Moreland St. Stockton, CA Inspection Aug5, 2014 <br /> Name: Address: Date: g <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M7) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 1 1 X I lother:HSC 25404(e)(4) See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 104. Current financial responsibility documents have not been uploaded into the California Electronic <br /> Reporting System(CERS). The most recent copy submitted to EHD was dated 8-1-13. Current financial <br /> responsibility documents are required to be submitted annually. Immediately submit a copy of the <br /> financial responsibility documents to the EHD. Log into CERS, upload the required information, and <br /> submit for review by the EHD. Complete by 9-25-14. <br /> 105. UST Information for the 91 and diesel tanks are not current in CERS. Tank primary containment <br /> should list fiberglass. Any change of information must be updated in CERS within 30 days of the <br /> changes. Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. Complete a separate tank form for each tank. <br /> 106. The monitoring plan in CERS is neither current nor approved by the EHD. The monitoring panel <br /> model for the USTs throughout the plan should list TLS-350R. The tank leak sensor model # should list <br /> 303 for all three tanks. The Under Dispenser Containment monitoring for all USTs should list "NO" for <br /> stopping flow of product at the dispenser. The diesel UST should list leak sensor model # 208 (304) in <br /> the section entitled Pipe Monitoring Is Performed Using The Following Methods. The monitoring and <br /> response plans must be current and approved by the EHD. Immediately log into CERS, update the <br /> required information, and submit for review by the EHD. Complete a separate record for each tank. <br /> Maintain an approved copy on site. <br /> 107. The plot plan/site map has not been uploaded into CERS. The plot plan/site map which shows <br /> where the monitoring is performed must be uploaded into CERS. Immediately log into CERS, upload the <br /> plot plan/site map which shows where the monitoring is performed, and submit for review by the EHD. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By: LZI Title. <br /> EHD 23-02 Rev 04/19/12 Page f UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.