Laserfiche WebLink
' 801513, BTEX by EPA Method 8021B, and MTBE, TAME, ETBE, DIPE, TBA, 1,2-DCA, and EDB by <br /> EPA Method 8260B <br /> Vapor Analytical Results <br /> ' Influent and effluent vapor samples were collected from the vapor extraction system during the fourth <br /> quarter 2005 on October 28 and November 21, 2005 Influent and effluent vapor samples were not <br /> collected from the vapor extraction system on December 27, 2005, since the system had shut down due to a <br /> system malfunction <br /> Gross range organics(GRO), the TPHg equivalent,were detected in the influent vapor samples collected on <br /> October 28 and November 21, 2005, at concentrations of 9 parts per million by volume (ppmv) and 50 <br /> ppmv, respectively Benzene was detected In the Influent vapor samples collected on October 28 and <br /> November 21, 2005,at concentrations of 0 072 ppmv and 0 60 ppmv, respectively Toluene was detected in <br /> the influent vapor samples collected on October 28 and November 21, 2005, at concentrations of 0 097 <br /> ' ppmv and 0 59 ppmv, respectively Ethylbenzene was detected In the influent vapor samples collected on <br /> October 28 and November 21, 2005, at concentrations of 0 062 ppmv and 0 19 ppmv, respectively Total <br /> xylenes were detected In the Influent vapor samples collected on October 28 and November 21, 2005, at <br /> ' concentrations of 0 43 ppmv and 101 ppmv, respectively MTBE, TBA, TAME, ETBE, DIPE, 1,2-DCA, <br /> and EDB were not detected In the Influent vapor samples collected on October 28 and November 21,2005 <br /> ' GRO was detected In the effluent sample collected on November 21, 2005, at a concentration of 6 ppmv <br /> Toluene was detected In the effluent sample collected on November 21, 2005, at a concentration of 0 13 <br /> ppmv Total xylenes were detected in the effluent sample on November 21,2005, at a concentration of 0 67 <br /> ppmv MTBE, TBA, TAME, ETBE, DIPE, 1,2-DCA, and EDB were not detected In the effluent vapor <br /> samples collected on November 21, 2005 None of the analytes of Interest were detected in the vapor <br /> sample collected on October 28, 2005 <br /> A summary of vapor analytical data is provided In Table 4 Groundwater laboratory data sheets and chain- <br /> of-custody documentation are contained in Attachment 4 <br /> ' Water Treatment System Analytical Results <br /> The Influent, vessel 1, and effluent water samples from the treatment and discharge component of the <br /> vapor extraction system were sampled during the fourth quarter 2005 on October 28, November 21, and <br /> December 27, 2005 <br /> TPHg, BTEX, MTBE, TBA, TAME, ETBE, DIPE, 1,2-DCA, and EDB were not detected in any of the <br /> Influent, vessel 1, and effluent water samples collected on October 28, November 21, and December 27, <br /> 2005,from the treatment and discharge component of the vapor extraction system <br /> ' A summary of analytical results Is presented In Table 5 Groundwater laboratory data sheets and chain- <br /> of-custody documentation are contained In Attachment 2 <br /> ' Air Sparge System Monitoring <br /> The air sparge system operated continuously from October 7 to November 21, 2005 On December 27, <br /> 2005, a cracked "T"point was observed in association with the air sparge system piping Subsequently the <br /> air sparge system was shut off untl l the part could be replaced <br /> s lenviro1625961quari1yAgr-2005 doc 6 ATC ASSOCIATES INC <br />