Central Valley Construction <br /> 146 Klo Road, Lathrop - 2 - 8 February 2002 <br /> areas was also sampled on 14 November 2001 for the same constituents as above, and was non-detect for all <br /> analyses. The groundwater flow direction as determined on 5 November 2001 is to the northeast at <br /> 0.0007 feet/feet. The on-site domestic well is cross gradient to MW-2 and the remaining soil contamination. <br /> JCA concluded that they will continue monitoring and sampling for three additional quarters, and that the well <br /> receptor survey still needs to be completed. <br /> For the next quarterly monitoring report, which is due on or before 30 March 2002,please complete and submit <br /> the following items: <br /> • Analyze groundwater samples from the three monitoring wells and the on-site domestic well for TPHg <br /> and TPHd by EPA Method 8015M, and for a full suite of volatile organic compounds by EPA Method <br /> 8260B analytes including fuel oxygenates, 1,2-dichloroethane, and ethylene dibromide, and report all <br /> peaks. If fuel oxygenates are not detected in this next sampling event,you may request that they be <br /> dropped from the constituent list. <br /> • Analyze groundwater samples from the three monitoring wells for dissolved lead by appropriate methods, <br /> and field filter the water samples. <br /> • Provide the results of all soil sampling relating to the UST and AGT investigation in a table. The table <br /> must include pre-excavation soil samples results collected in April 2001,post-excavation soil sample <br /> results collected in August 2001,results from soil samples collected from monitoring well installation in <br /> November 2001, and results from all additional soil samples collected for investigation of this project. <br /> • Provide the results of all groundwater sampling relating to the UST and AGT investigation in a table. The <br /> table must include the pre-excavation water sample result,results from water samples collected from the <br /> on-site domestic well, and results of sampling the three on-site monitoring wells. The data must show <br /> detection limits for samples analyzed. <br /> • Complete a well receptor su'yey within 2,000 feet of the site, show all wells identified on a map,and <br /> provide well construction details for all identified wells in a table. <br /> • Submit a plan of work to define the lateral and vertical extent of soil contamination at the former AGT <br /> area and estimate the mass of contamination remaining in soils. I suggest using a push probe type soil <br /> sampling apparatus to define the vertical soil profile. <br /> If you have any questions or comments,please call me at(916) 255-3115. Please notify me at least five business <br /> days prior to any site work or sampling. <br /> Marty Hartzell,R.G. <br /> Associate Engineering Geologist <br /> cc: Mr. Sam Savig, San Joaquin County Public Health Services, Stockton <br /> Mr. John Cummings, John Cummings&Associates,Fremont <br />