Laserfiche WebLink
� ED <br /> TABLE 2 <br /> Dual Phase Extraction Vapor Field Data <br /> SUPER CENTER MART ENVIRONMENTAL <br /> 701 East Charter Way, Stockton, CA HEALTH DEPARTMENT <br /> Oxidizer DPE Liquid <br /> Hours of Total Air Flow Influent PID Effluent PID <br /> Date Operation (SCFM <br /> eration Operational DPE Wells Temperature Ring Vacuum my my <br /> ) (pp ) (pp ) <br /> (°F) (in. Hg) <br /> 12/19/2013 11,582.6 MW-1, MW-2, MW-3 650 20.5 82 54 1 <br /> 12/26/2013 11,749.7 MW-1, MW-2, MW-3 650 21 82 84 1 <br /> 1/2/2014 11,923.4 MW-1, MW-2, MW-3 650 21 87 39 0 <br /> 1/7/2014 12,037.5 MW-1, MW-2, MW-3 650 21.5 81 45 0 <br /> 1/8/2014 12,057.6 MW-1, MW-2, MW-3 655 24 - 20.3 0 <br /> 1/14/2014 12,201.9 MW-1, MW-2, MW-3 650 21.5 87 41 0 <br /> 1/20/2014 12,345.3 MW-1, MW-2, MW-3 650 21.5 85 29 0 <br /> 1/29/2014 1.5 12,468.0 MW-1, MW-2, MW-3 650 23 73 55 0 <br /> NOTES' <br /> SCFM:standard cubic feet per minute <br /> PPMV:parts per million volume <br /> °F:degrees in Fahrenheit <br /> :samples collected for laboratory analysis <br /> Z:DPE unit shutdown for repairs <br /> 3:DPE unit restarted after a shutdown <br /> 4:DPE unit shutdown due to exhaustion of USTF funding <br /> Advanced GeoEnviron mental,Inc. <br />