Laserfiche WebLink
Site Safety Plan March 23, 1990 <br /> Arco Station No. 2076, Lodi, California AGS 30008-IS <br /> HAZARD ASSESSMENT" <br /> The major contaminants expected to be encountered on the project are gasoline and its <br /> hydrocarbon constituents. The anticipated contaminants and their exposure standards are <br /> listed in Table 1. It is not anticipated that the potential levels of exposure will reach the <br /> permissible exposure limits(PEL)or threshold limit values(TLV). Inhalation and dermal <br /> contact are the potential exposure pathways. Protective clothing will be mandatory for <br /> field personnel specified in this PIan. In addition, respiratory protective devices are <br /> required to be wom by each person onsite or to be within easy reach should irritating odors <br /> be detected or irritation of the respiratory tract occur. <br /> TABLE I <br /> N EXPOSURE LIMITS OF ANTICIPA'T'ED CHEMICAL CONTAMINANTS <br /> Arco Service Station Nc. 2076 <br /> 600 East Kettleman Lane <br /> Lodi, California <br /> (Page I of 2) <br /> Contaminant PEL EL ED CL TWA STEL <br /> Benzene (skin] 1* -- _- ____ _ <br /> & (carc] -- -- 10* 5* <br /> Et:hylbenzene 100* --- ------ --- <br /> 100* 125* <br /> Gasoline2 300* - ------ <br /> --- 300* 500* <br /> Toluene [skin] 100* 200* 10 min per 50o* 100* 150* <br /> B hrs. - <br /> i <br /> Xyle s (o,m, 1o0* 200* <br /> 30 min per 300* 200* 150* <br /> P isomers) S' hrs <br /> [skin] <br /> See notes on page 2 of 2. <br /> Al <br /> Appl/eaf 10490systeme <br />