SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
3500 - Local Oversight Program
>
PR0545339
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2020 7:36:58 PM
Creation date
2/11/2020 4:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545339
PE
3528
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
02
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chuck. Carmel Page 3 <br /> immediately. Remediation will proceed when the contamination has been defined and equipment is <br /> available. <br /> Facility 434 at Sol W. Kettleman Lane, Lodi <br /> PHS/EHD contact - Margaret L.agorio <br /> Extraction of the groundwater was started but grou dwater sample results indicated contamination <br /> was non-detectable so the system was turned off. Tl�e system will be operated intermittently. If the <br /> sample results continue to indicate non-detect, the groundwater extraction system will not be used. <br /> Monitoring well MW-2 is biofouled. Attempts of jet ing and ramming it out have been unsuccessful. <br /> Vapor extraction and quarterly monitoring will cont ue. <br /> i <br /> Facility 6100 at 25773 Patterson Pass Road,Tracy <br /> PHS/EHD contact - Margaret Lagorio <br /> Soil boring B-26,drilled on the other side of Patterson Pass Road,from the station,showed evidence <br /> of soil contamination to a depth of 110 feet. Additional investigation of the soil has been proposed. <br /> Depth to groundwater for this site remains to be confirmed. The on-site water supply well depth to <br /> water after its development was 100 feet below ground surface. PHS/EHD requests the current depth <br /> to water in this well be determined. Site investigation will continue and remediation will proceed j <br /> when the investigation has been completed and equipment is available. <br /> Facility 2093 at 3425 N.Tracy Boulevard,Tracy <br /> PHS/EHD contact - Harlin Knoll <br /> This site has soil and groundwater contamination with one on-site well containing free phase i! <br /> petroleum hydrocarbon. Arco and Brown&Caldwell i plan to install piping to the existing monitoring <br /> well and begin vapor extraction soon. Groundwater monitoring and sampling will continue on a <br /> quarterly basis until cleanup is complete. <br /> Facility 760 at 225 S. Cherokee Lane, Lodi <br /> PHS/EHD contact - Linda Turkatte <br /> i <br /> The current proposal for additional soil borings/vapor wells in the area to the west, to the north and <br /> to the east of the former waste oil tank was discussed and the additional work was considered to be <br /> warranted. <br /> s <br /> The area of B-5 and B-20/VW-10 was discussed. Although the laboratory results showed non-detect <br /> for the total depth of the borings,the field observations indicated the borings to be contaminated to <br /> their total depth. An explanation for the apparent discrepancies between the field observations and <br /> the laboratory results may be the way the samples were handled in the field before they were <br /> submitted to the laboratory. Nevertheless, this area is considered to be an area of concern for j <br /> PHS/EHD. However,it appears that it will be encompassed within the estimated radius of influence <br /> of the proposed remediation system and will be addressed. <br /> The new tank pit area was also discussed as an area of concern for PHS/EHD. Contamination was <br /> noted during soil sampling at 12 feet below ground surface (BGS) in this area before the installation <br /> of the new tanks. However,the subsequent soil borings indicated non-detect conditions to their total <br /> depth of 20 feet BGS. It is unclear why the contamination was not detected in the subsequent borings <br /> and that additional confirmation work will need to be done to verify this area is no longer a problem. <br /> In addition,it was discussed that the estimate of the radius of influence of the remediation system may <br /> be conservative and RESNA feels that the remediation efforts would also reach this area. <br />