Laserfiche WebLink
SANJ 0 A N ` , Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 99 SHELL' 1 7700 MORELAND ST STOCKTON August 29 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) o V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284; CCR 2711(d) Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit <br /> fees. <br /> A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit for <br /> its operation has been issued by the local agency to the owner or operator of the UST system. Immediately obtain a <br /> permit to operate a UST system from the EHD. An"Operating without a Permit"penalty applies. <br /> This is a Class I violation. <br /> 107 CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. <br /> -The site plan on CERS is missing the general layout of piping. <br /> A site plan must be submitted identifying the locations where monitoring will be performed. The site plan must show <br /> the general layout of tanks and piping and clearly identify locations of the following equipment, if installed: 1) <br /> monitoring system control panels; 2)in-tank liquid level probes(if used for leak detection); 3)devices monitoring tank <br /> annular spaces or vault;4)devices monitoring product piping; 5)devices monitoring fill piping;6)devices monitoring <br /> vent piping; 7)devices monitoring vapor recovery piping; 8)devices monitoring vent/transition sumps; 9)devices <br /> monitoring under-dispenser containment; 10)line leak detectors; and 11)devices monitoring any other secondary <br /> containment areas. Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a Class II violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form"not submitted <br /> within 30 days. <br /> Erik Rogers is performing designated operator inspections at the facility and is not listed on the submitted statement <br /> of designated operators.The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form"no later than 30 days after any change in the designated UST operator(s). Immediately log into <br /> the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov and upload the notification <br /> identifying all the designated operators for this facility. <br /> This is a Class II violation. <br /> FA0003732 PR0231819 SCO01 08/29/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />