Discussion of Soil Lithology <br /> Based on the soil observed in the boring, there appears to be limited potential for <br /> percolation in the shallow soil zone. Sandy soils generally have a much greater <br /> potential for percolation than fine-grained or cemented soils. However, a percolation <br /> test is the only accepted method for determining the suitability of the soils for a septic <br /> disposal area. Percolation test results are discussed in the following section. <br /> Percolation Test <br /> A shallow percolation test was conducted in the proposed septic disposal area of the <br /> Site. The soil boring discussed above was used for the percolation test hole. <br /> Percolation test procedures conformed to San Joaquin County Environmental Health <br /> Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the boring was advanced by hand auger and the soil logged, the test hole was <br /> completed for the percolation testing. Approximately two inches of pea gravel were <br /> placed in the bottom of the open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br /> percolation testing. The hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the hole was found to <br /> be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the boring on December 5, 2019. Due to <br /> the soil type present, a four-hour test was selected. Water level measurements were <br /> taken every 30 minutes during the four-hour period. The last 30 minutes of the test <br /> were observed by Sukhreet Kaur, Registered Environmental Health Specialist at the <br /> San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of six inches or more above the bottom of the hole. <br /> LOGE 20-01 Page 5 <br />