Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sj_oq v^or,/q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DBA CIRCLEK, REFUEL PETROLEUM INC. 419 S MAIN ST, MANTECA May 15, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> For TA0143301 (regular unleaded), change "Yes" to"No" for Automatic Tank Gauging, beneath Mechanical Line <br /> Leak Detector Performs 3 GPH Leak Test, beneath MLLD Manufacturer, change MDDL Manufacturer to Vaporless <br /> and enter 99LD2000 for the MLLD Model; change "Yes"to"No" for Electronic Line Leak Detector Performs 3 GPH <br /> Leak Test; change"Yes" to"No"for Visual Pipeline Monitoring"; change "Yes"to"No"for No Regulated Piping Per <br /> Health and Safety Code, Division 20, Chapter 6.7 Is Connected to the Tank System; beneath Under Dispenser <br /> Containment(UDC) Monitoring, change "Float and Chain Assembly to Continuous, remove"liquid" form UDC <br /> Secondary Containment Monitoring, and remove"Yes" from Leak Within Secondary Containment of UDC Causes <br /> Audible and Visual Alarms; beneath Training, change"No"to "Yes" for designated operator training; and under <br /> Personnel Responsibilities, remove Kuljit Mangat from the first person Having Responsibility. <br /> For TA0143302 (Premium Unleaded), change "Yes"to "No" for Automatic Tank Gauging; beneath Mechanical Line <br /> Leak Detector Performs 3 GPH Leak Test, enter Veeder Root for MLLD manufacturer, and enter FXIV for the MLLD <br /> Model; change"Yes"to"No" for Electronic Line Leak Detector Performs 3 GPH Leak Test; change "Yes"to"No" <br /> for Visual Pipeline Monitoring; beneath Under Dispenser Containment(UDC) Monitoring, change Float and Chain <br /> Assembly to Continuous, change FXIV to 208 for UDC Leak Sensor Model, remove"Liquid" from UDC Secondary <br /> Containment Monitoring, and remove"Yes"from Leak Within Secondary Containment of UDC Causes Audible and <br /> Visual Alarms; beneath Training, change"No' to"Yes" for Designated Operator Training, and beneath "Personnel <br /> Responsibilities, remove Kuljit Mangat from Name of First Person Having Responsibility. <br /> For TA0143303 (Diesel), change"Yes"to"No" for Automatic Tank Gauging, change"Yes"to"No"for Tank Integrity <br /> Testing,; remove"Yes"from Other Monitoring; beneath Mechanical Line Leak Detector Performs 3 GPH Leak Test, <br /> enter Veeder Root for MLLD Manufacturer, and enter FXIV for MLLD Model; remove"Yes"from Electronic Line <br /> Leak Detector Performs 3 GPH Leak Test; remove"Yes"from Visual Pipeline Monitoring, change"Yes"to"No" for <br /> No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected to the Tank System; <br /> beneath Under Dispenser Containment(UDC) Monitoring, remove Veeder Root from UDC Panel Manufacturer, <br /> remove TLS350 from UDC Panel Model#, remove Veeder Root from UDC Leak Sensor Manufacturer, and remove <br /> VR-208 from UDC Leak Sensor Model, change"Yes" to"No"for Detection of Leak into UDC Triggers Audible and <br /> Visual Alarms, UDC Leak Alarm Triggers Automatic Pump Shutdown, Failure/Disconnection of UDC Monitoring <br /> System Triggers Automatic Pump Shutdown, remove"liquid" from UDC Secondary Containment Monitoring and <br /> remove "Yes"from Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms; beneath <br /> Training, change"No" to"Yes"for Designated Operator Training; and beneath Personnel Responsibilities, remove <br /> Kuljit Mangat from Name of First Person Having Responsibility. <br /> . The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately <br /> log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Remove"V"for vapor from the diesel tank, add the line <br /> leak detectors to the site map and enter sensor after the word "Annular" in the Key. A site plan must be submitted <br /> identifying the locations where monitoring will be performed. Immediately log into the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> FA0003685 PR0231433 SCO01 05/15/2017 <br /> EHD 23-01 Rev.09/22/16 Page 5 of 7 Underground Storage Tank Program OIR <br />