My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITOING SYSTEM CERTACATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: MANTECA EXPRESS Bldg. No.: <br /> Site Address: 419 S.MAIN STREET City: MANTECA I Zip: 95336 <br /> Facility Contact Person: BOBBY MANGAT Contact Phone No.: (209)401-5292 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: APR 9, 2008 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> rTankID:91 Tank ID:87 <br /> Tank Gauging Probe. Model:MAG ®In-Tank Gauging Probe. Model:MAG <br /> nular Space or Vault Sensor. Model:420 ®Annular Space or Vault Sensor. Model:420 <br /> ping Sump/Trench Sensor(s). Model: 208 ®Piping Sump/Trench Sensor(s). Model:208 <br /> l Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model:LD 2000 ®Mechanical Line Leak Detector. Model:FXIV <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:FLOAT ®Tank Overfill/High-Level Sensor. Model:FLOAT <br /> ❑Other(s2ecify equipment a and model in Section E on Pae 2). ❑Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID:DIESEL Tank ID: <br /> ®In-Tank Gauging Probe. Model:MAG ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model:420 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model:208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model:FXIV ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: FLOAT ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment e and model in Section E on Page 2). ❑ Other(specifZ equipment a and model in Section E on Page 2). <br /> Dispenser ID: 1 -2 Dispenser ID:33=4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Floats and Chains . ❑Dispenser Containment Floats and Chains . <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑Dispenser Containment Float(s)and Chain (s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to the Certification is information(e.g.manufacturers' checklists)necessary to verify that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the <br /> report; (check all that apply): ® System set-up ® Alarm history report <br /> Technician Name(print): MIKE LAWRENCE Signature: <br /> Certification No:A26642 License: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION I Phone No: (707)446-6151 <br /> Address: 607 ELMIRA RD, PMB 336, VA CAVILLE, CA 95687 Date of Testing/Servicing: APR 9, 2008 <br /> Pagel of 3 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.